TY - JOUR
T1 - Comparison of cardiac energetics after transcatheter and surgical aortic valve replacements
AU - Yamashita, Yoshiyuki
AU - Tanoue, Yoshihisa
AU - Sonoda, Hiromichi
AU - Ushijima, Tomoki
AU - Kimura, Satoshi
AU - Oishi, Yasuhisa
AU - Tatewaki, Hideki
AU - Hiasa, Kenichi
AU - Arita, Takeshi
AU - Shiose, Akira
N1 - Publisher Copyright:
© The Author(s) 2018.
Copyright:
Copyright 2021 Elsevier B.V., All rights reserved.
PY - 2019/4/1
Y1 - 2019/4/1
N2 - OBJECTIVES: The effect of transcatheter aortic valve replacement (TAVR) on cardiac energetics has not been described. We compared changes in cardiac energetics after TAVR with those after surgical aortic valve replacement (SAVR). METHODS: We retrospectively estimated end-systolic elastance (Ees) and effective arterial elastance (Ea) using blood pressure and left ventricular (LV) volume obtained from echocardiography. LV efficiency [ventriculoarterial coupling (Ea/Ees) and the stroke work to pressure-volume area ratio (SW/PVA)] was calculated. Measurements were taken before, 1 week after and 1 year after bioprosthetic aortic valve replacement (TAVR, n = 56; SAVR, n = 61) in patients with severe aortic stenosis and preserved ejection fraction. RESULTS: Patients with TAVR had a lower aortic valve pressure gradient and larger stroke volume 1 week after the procedure than those with SAVR. Ea was more markedly decreased, and LV efficiency was significantly improved 1 week after TAVR (SW/PVA 68.1% ± 8.4% to 72.0% ± 8.5%, P < 0.001), but LV efficiency was unchanged 1 week after SAVR (SW/PVA 70.1% ± 7.4% to 69.1% ± 8.0%). LV efficiency was improved 1 year after both procedures (SW/PVA 75.5% ± 6.1% in TAVR; 74.7% ± 6.4% in SAVR). CONCLUSIONS: TAVR decreases the transvalvular pressure gradient further without deteriorating stroke volume in the early postoperative period, which is accompanied by early improvement in afterload and LV efficiency compared with SAVR. Improvement in LV efficiency at mid-term follow-up is satisfactory after both procedures.
AB - OBJECTIVES: The effect of transcatheter aortic valve replacement (TAVR) on cardiac energetics has not been described. We compared changes in cardiac energetics after TAVR with those after surgical aortic valve replacement (SAVR). METHODS: We retrospectively estimated end-systolic elastance (Ees) and effective arterial elastance (Ea) using blood pressure and left ventricular (LV) volume obtained from echocardiography. LV efficiency [ventriculoarterial coupling (Ea/Ees) and the stroke work to pressure-volume area ratio (SW/PVA)] was calculated. Measurements were taken before, 1 week after and 1 year after bioprosthetic aortic valve replacement (TAVR, n = 56; SAVR, n = 61) in patients with severe aortic stenosis and preserved ejection fraction. RESULTS: Patients with TAVR had a lower aortic valve pressure gradient and larger stroke volume 1 week after the procedure than those with SAVR. Ea was more markedly decreased, and LV efficiency was significantly improved 1 week after TAVR (SW/PVA 68.1% ± 8.4% to 72.0% ± 8.5%, P < 0.001), but LV efficiency was unchanged 1 week after SAVR (SW/PVA 70.1% ± 7.4% to 69.1% ± 8.0%). LV efficiency was improved 1 year after both procedures (SW/PVA 75.5% ± 6.1% in TAVR; 74.7% ± 6.4% in SAVR). CONCLUSIONS: TAVR decreases the transvalvular pressure gradient further without deteriorating stroke volume in the early postoperative period, which is accompanied by early improvement in afterload and LV efficiency compared with SAVR. Improvement in LV efficiency at mid-term follow-up is satisfactory after both procedures.
UR - http://www.scopus.com/inward/record.url?scp=85063712918&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85063712918&partnerID=8YFLogxK
U2 - 10.1093/icvts/ivy292
DO - 10.1093/icvts/ivy292
M3 - Article
C2 - 30364945
AN - SCOPUS:85063712918
SN - 1569-9293
VL - 28
SP - 587
EP - 593
JO - Interactive Cardiovascular and Thoracic Surgery
JF - Interactive Cardiovascular and Thoracic Surgery
IS - 4
ER -