Cyclic AMP detection by electrode modified with 17mer oligopeptide

Yoshiki Katayama, Yuya Ohuchi, Masamichi Nakayama, Mizuo Maeda, Hideyoshi Higashi, Yoshihisa Kudo

研究成果: ジャーナルへの寄稿記事

15 引用 (Scopus)

抄録

An oligopeptide (17mer) which recognizes cyclic AMP was designed and applied to electrochemical detection of cAMP. Redox peak currents on cyclic voltammograms of ferrocyanide/ferricyanide redox couple with Au electrode which was modified with the peptide showed response dependently on the cAMP concentration, while the electrode showed only slight response to ATP that is a structural analog of cAMP.

元の言語英語
ページ(範囲)883-884
ページ数2
ジャーナルChemistry Letters
発行部数9
DOI
出版物ステータス出版済み - 1 1 1997

Fingerprint

Oligopeptides
Cyclic AMP
Electrodes
Adenosine Triphosphate
Peptides
Oxidation-Reduction
hexacyanoferrate III
hexacyanoferrate II

All Science Journal Classification (ASJC) codes

  • Chemistry(all)

これを引用

Katayama, Y., Ohuchi, Y., Nakayama, M., Maeda, M., Higashi, H., & Kudo, Y. (1997). Cyclic AMP detection by electrode modified with 17mer oligopeptide. Chemistry Letters, (9), 883-884. https://doi.org/10.1246/cl.1997.883

Cyclic AMP detection by electrode modified with 17mer oligopeptide. / Katayama, Yoshiki; Ohuchi, Yuya; Nakayama, Masamichi; Maeda, Mizuo; Higashi, Hideyoshi; Kudo, Yoshihisa.

:: Chemistry Letters, 番号 9, 01.01.1997, p. 883-884.

研究成果: ジャーナルへの寄稿記事

Katayama, Y, Ohuchi, Y, Nakayama, M, Maeda, M, Higashi, H & Kudo, Y 1997, 'Cyclic AMP detection by electrode modified with 17mer oligopeptide', Chemistry Letters, 番号 9, pp. 883-884. https://doi.org/10.1246/cl.1997.883
Katayama, Yoshiki ; Ohuchi, Yuya ; Nakayama, Masamichi ; Maeda, Mizuo ; Higashi, Hideyoshi ; Kudo, Yoshihisa. / Cyclic AMP detection by electrode modified with 17mer oligopeptide. :: Chemistry Letters. 1997 ; 番号 9. pp. 883-884.
@article{51117b3e19ca4374b6f3a1b53dabdbdb,
title = "Cyclic AMP detection by electrode modified with 17mer oligopeptide",
abstract = "An oligopeptide (17mer) which recognizes cyclic AMP was designed and applied to electrochemical detection of cAMP. Redox peak currents on cyclic voltammograms of ferrocyanide/ferricyanide redox couple with Au electrode which was modified with the peptide showed response dependently on the cAMP concentration, while the electrode showed only slight response to ATP that is a structural analog of cAMP.",
author = "Yoshiki Katayama and Yuya Ohuchi and Masamichi Nakayama and Mizuo Maeda and Hideyoshi Higashi and Yoshihisa Kudo",
year = "1997",
month = "1",
day = "1",
doi = "10.1246/cl.1997.883",
language = "English",
pages = "883--884",
journal = "Chemistry Letters",
issn = "0366-7022",
publisher = "The Chemical Society of Japan",
number = "9",

}

TY - JOUR

T1 - Cyclic AMP detection by electrode modified with 17mer oligopeptide

AU - Katayama, Yoshiki

AU - Ohuchi, Yuya

AU - Nakayama, Masamichi

AU - Maeda, Mizuo

AU - Higashi, Hideyoshi

AU - Kudo, Yoshihisa

PY - 1997/1/1

Y1 - 1997/1/1

N2 - An oligopeptide (17mer) which recognizes cyclic AMP was designed and applied to electrochemical detection of cAMP. Redox peak currents on cyclic voltammograms of ferrocyanide/ferricyanide redox couple with Au electrode which was modified with the peptide showed response dependently on the cAMP concentration, while the electrode showed only slight response to ATP that is a structural analog of cAMP.

AB - An oligopeptide (17mer) which recognizes cyclic AMP was designed and applied to electrochemical detection of cAMP. Redox peak currents on cyclic voltammograms of ferrocyanide/ferricyanide redox couple with Au electrode which was modified with the peptide showed response dependently on the cAMP concentration, while the electrode showed only slight response to ATP that is a structural analog of cAMP.

UR - http://www.scopus.com/inward/record.url?scp=0031324095&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031324095&partnerID=8YFLogxK

U2 - 10.1246/cl.1997.883

DO - 10.1246/cl.1997.883

M3 - Article

AN - SCOPUS:0031324095

SP - 883

EP - 884

JO - Chemistry Letters

JF - Chemistry Letters

SN - 0366-7022

IS - 9

ER -