T1 - Detectability of a lung nodule displayed on a liquid-crystal display monitor with different maximum luminance settings
AU - Takahashi, Keita
AU - Sueoka, Masaki
AU - Yoon, Yongsu
AU - Hiwasa, Takeshi
AU - Hatanaka, Shiro
AU - Nakamura, Yasuhiko
AU - Hashimoto, Noriyuki
AU - Ohki, Masafumi
AU - Morishita, Junji
N1 - Funding Information:
M. Sueoka Foundation for Biological Research and Innovation, Institute of Biomedical Research and Innovation, Minamimachi, Minatojima, Chuo-ku, Kobe, Hyogo 650-0047, Japan
PY - 2010/1
Y1 - 2010/1
N2 - Our purpose in this study was to examine the detectability of a lung nodule at different maximum luminance settings of a liquid-crystal display (LCD) monitor by utilizing receiver operating characteristic (ROC) analysis. The LCD monitor used in this study was calibrated to the grayscale standard display function with different maximum luminance settings (670, 450, and 170 cd/m 2). The average area under the ROC curve (AUC) and the standard deviation for all observers at 670, 450, and 170 cd/m2 were 0.837 ± 0.076, 0.832 ± 0.051, and 0.830 ± 0.078, respectively. There was no statistically significant difference in AUC as a function of the maximum luminance setting of the LCD monitor. Considering the results, setting the maximum luminance of an LCD monitor at a higher level may not provide a significant advantage in the detectability of a lung nodule.
AB - Our purpose in this study was to examine the detectability of a lung nodule at different maximum luminance settings of a liquid-crystal display (LCD) monitor by utilizing receiver operating characteristic (ROC) analysis. The LCD monitor used in this study was calibrated to the grayscale standard display function with different maximum luminance settings (670, 450, and 170 cd/m 2). The average area under the ROC curve (AUC) and the standard deviation for all observers at 670, 450, and 170 cd/m2 were 0.837 ± 0.076, 0.832 ± 0.051, and 0.830 ± 0.078, respectively. There was no statistically significant difference in AUC as a function of the maximum luminance setting of the LCD monitor. Considering the results, setting the maximum luminance of an LCD monitor at a higher level may not provide a significant advantage in the detectability of a lung nodule.
UR - http://www.scopus.com/inward/record.url?scp=77649184749&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77649184749&partnerID=8YFLogxK
U2 - 10.1007/s12194-009-0070-5
DO - 10.1007/s12194-009-0070-5
M3 - Article
C2 - 20821096
AN - SCOPUS:77649184749
SN - 1865-0333
VL - 3
SP - 10
EP - 15
JO - Radiological Physics and Technology
JF - Radiological Physics and Technology
IS - 1
ER -