TY - GEN
T1 - Detection of hematopoietic stem cells in microscopy images using a bank of ring filters
AU - Eom, Sungeun
AU - Bise, Ryoma
AU - Kanade, Takeo
N1 - Copyright:
Copyright 2010 Elsevier B.V., All rights reserved.
PY - 2010
Y1 - 2010
N2 - We present a method for robustly detecting hematopoietic stem cells (HSCs) in phase contrast microscopy images. HSCs appear to be easy to detect since they typically appear as round objects. However, when HSCs are touching and overlapping, showing the variations in shape and appearance, standard pattern detection methods, such as Hough transform and correlation, do not perform well. The proposed method exploits the output pattern of a ring filter bank applied to the input image, which consists of a series of matched filters with multiple-radius ring-shaped templates. By modeling the profile of each filter response as a quadratic surface, we explore the variations of peak curvatures and peak values of the filter responses when the ring radius varies. The method is validated on thousands of phase contrast microscopy images with different acquisition settings, achieving 96.5% precision and 94.4% recall.
AB - We present a method for robustly detecting hematopoietic stem cells (HSCs) in phase contrast microscopy images. HSCs appear to be easy to detect since they typically appear as round objects. However, when HSCs are touching and overlapping, showing the variations in shape and appearance, standard pattern detection methods, such as Hough transform and correlation, do not perform well. The proposed method exploits the output pattern of a ring filter bank applied to the input image, which consists of a series of matched filters with multiple-radius ring-shaped templates. By modeling the profile of each filter response as a quadratic surface, we explore the variations of peak curvatures and peak values of the filter responses when the ring radius varies. The method is validated on thousands of phase contrast microscopy images with different acquisition settings, achieving 96.5% precision and 94.4% recall.
UR - http://www.scopus.com/inward/record.url?scp=77955220719&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77955220719&partnerID=8YFLogxK
U2 - 10.1109/ISBI.2010.5490394
DO - 10.1109/ISBI.2010.5490394
M3 - Conference contribution
AN - SCOPUS:77955220719
SN - 9781424441266
T3 - 2010 7th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, ISBI 2010 - Proceedings
SP - 137
EP - 140
BT - 2010 7th IEEE International Symposium on Biomedical Imaging
T2 - 7th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, ISBI 2010
Y2 - 14 April 2010 through 17 April 2010
ER -