T1 - Detection of masses and microcalcifications of breast cancer on digital mammograms
T2 - Comparison among hard-copy film, 3-megapixel liquid crystal display (LCD) monitors and 5-megapixel LCD monitors: An observer performance study
AU - Kamitani, Takeshi
AU - Yabuuchi, Hidetake
AU - Soeda, Hiroyasu
AU - Matsuo, Yoshio
AU - Okafuji, Takashi
AU - Sakai, Shuji
AU - Furuya, Akio
AU - Hatakenaka, Masamitsu
AU - Ishii, Nobuhide
AU - Honda, Hiroshi
N1 - Copyright:
Copyright 2008 Elsevier B.V., All rights reserved.
PY - 2007/5
Y1 - 2007/5
N2 - The purpose of the study was to compare observer performance in the detection of masses and microcalcifications of breast cancer among hard-copy reading and soft-copy readings using 3-megapixel (3M) and 5-megapixel (5M) liquid crystal display (LCD) monitors. For the microcalcification detection test, we prepared 100 mammograms: 40 surgically verified cancer cases and 60 normal cases. For the mass detection test, we prepared 100 mammograms: 50 cancer cases and 50 normal cases. After six readers assessed both microcalcifications and masses set for each modality, receiver operating characteristic (ROC) analysis was performed. The average Azs for mass detection using a hard copy and 3M and 5M LCD monitors were 0.923, 0.927 and 0.920, respectively; there were no significant differences. The average Az for microcalcification detection using hard copy, 3M and 5M LCD monitors was 0.977, 0.954 and 0.972, respectively. There were no significant differences, but the P-values between the hard copy and 3M LCD monitor and that between the 3M and 5M LCD monitor were 0.08 and 0.09, respectively. In conclusion, the observer performances for detecting masses of breast cancers were comparable among the hard copy and two LCD monitors; however, soft-copy reading with a 3M LCD monitor showed slightly lower observer performance for detecting microcalcifications of breast cancers than hard-copy or 5M LCD monitor reading.
AB - The purpose of the study was to compare observer performance in the detection of masses and microcalcifications of breast cancer among hard-copy reading and soft-copy readings using 3-megapixel (3M) and 5-megapixel (5M) liquid crystal display (LCD) monitors. For the microcalcification detection test, we prepared 100 mammograms: 40 surgically verified cancer cases and 60 normal cases. For the mass detection test, we prepared 100 mammograms: 50 cancer cases and 50 normal cases. After six readers assessed both microcalcifications and masses set for each modality, receiver operating characteristic (ROC) analysis was performed. The average Azs for mass detection using a hard copy and 3M and 5M LCD monitors were 0.923, 0.927 and 0.920, respectively; there were no significant differences. The average Az for microcalcification detection using hard copy, 3M and 5M LCD monitors was 0.977, 0.954 and 0.972, respectively. There were no significant differences, but the P-values between the hard copy and 3M LCD monitor and that between the 3M and 5M LCD monitor were 0.08 and 0.09, respectively. In conclusion, the observer performances for detecting masses of breast cancers were comparable among the hard copy and two LCD monitors; however, soft-copy reading with a 3M LCD monitor showed slightly lower observer performance for detecting microcalcifications of breast cancers than hard-copy or 5M LCD monitor reading.
UR - http://www.scopus.com/inward/record.url?scp=34247893922&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=34247893922&partnerID=8YFLogxK
U2 - 10.1007/s00330-006-0452-6
DO - 10.1007/s00330-006-0452-6
M3 - Article
C2 - 17093968
AN - SCOPUS:34247893922
SN - 0938-7994
VL - 17
SP - 1365
EP - 1371
JO - European Radiology
JF - European Radiology
IS - 5
ER -