Development of a 3D reconstruction of blood vessel by positional calibration of ultrasound probe

Yuki Sugano, Shinya Onogi, Antoine Bossard, Takashi Mochizuki, Kohji Masuda

研究成果: 著書/レポートタイプへの貢献会議での発言

3 引用 (Scopus)

抄録

We have ever developed the method to realize active path selection of microbubbles at the bifurcation of blood vessel by introducing acoustic radiation force to focus the density. To apply this method to an in vivo experiment, it is necessary to understand the three-dimensional shape of blood vessel and the distribution of bifurcations. Therefore we have developed a method to measure the distribution of bifurcations in blood vessel by positional calibration of the ultrasound probe with the extraction of blood flow in echograms. We used a metal ball marker for calibration. The shape of blood vessels is reconstructed in a graphical interface, where three-dimensional thinning algorithm was applied. This system helps the examiner to adjust the acoustic field for ultrasound therapy using microbubbles.

元の言語英語
ホスト出版物のタイトル5th 2012 Biomedical Engineering International Conference, BMEiCON 2012
DOI
出版物ステータス出版済み - 12 1 2012
イベント5th 2012 Biomedical Engineering International Conference, BMEiCON 2012 - Muang, Ubon Ratchathani, タイ
継続期間: 12 5 201212 7 2012

その他

その他5th 2012 Biomedical Engineering International Conference, BMEiCON 2012
タイ
Muang, Ubon Ratchathani
期間12/5/1212/7/12

Fingerprint

Blood vessels
Ultrasonics
Calibration
Acoustic fields
Blood
Acoustics
Radiation
Metals
Experiments

All Science Journal Classification (ASJC) codes

  • Biomedical Engineering

これを引用

Sugano, Y., Onogi, S., Bossard, A., Mochizuki, T., & Masuda, K. (2012). Development of a 3D reconstruction of blood vessel by positional calibration of ultrasound probe. : 5th 2012 Biomedical Engineering International Conference, BMEiCON 2012 [6465483] https://doi.org/10.1109/BMEiCon.2012.6465483

Development of a 3D reconstruction of blood vessel by positional calibration of ultrasound probe. / Sugano, Yuki; Onogi, Shinya; Bossard, Antoine; Mochizuki, Takashi; Masuda, Kohji.

5th 2012 Biomedical Engineering International Conference, BMEiCON 2012. 2012. 6465483.

研究成果: 著書/レポートタイプへの貢献会議での発言

Sugano, Y, Onogi, S, Bossard, A, Mochizuki, T & Masuda, K 2012, Development of a 3D reconstruction of blood vessel by positional calibration of ultrasound probe. : 5th 2012 Biomedical Engineering International Conference, BMEiCON 2012., 6465483, 5th 2012 Biomedical Engineering International Conference, BMEiCON 2012, Muang, Ubon Ratchathani, タイ, 12/5/12. https://doi.org/10.1109/BMEiCon.2012.6465483
Sugano Y, Onogi S, Bossard A, Mochizuki T, Masuda K. Development of a 3D reconstruction of blood vessel by positional calibration of ultrasound probe. : 5th 2012 Biomedical Engineering International Conference, BMEiCON 2012. 2012. 6465483 https://doi.org/10.1109/BMEiCon.2012.6465483
Sugano, Yuki ; Onogi, Shinya ; Bossard, Antoine ; Mochizuki, Takashi ; Masuda, Kohji. / Development of a 3D reconstruction of blood vessel by positional calibration of ultrasound probe. 5th 2012 Biomedical Engineering International Conference, BMEiCON 2012. 2012.
@inproceedings{11203547b9864016a26c4a9b8fcfdc86,
title = "Development of a 3D reconstruction of blood vessel by positional calibration of ultrasound probe",
abstract = "We have ever developed the method to realize active path selection of microbubbles at the bifurcation of blood vessel by introducing acoustic radiation force to focus the density. To apply this method to an in vivo experiment, it is necessary to understand the three-dimensional shape of blood vessel and the distribution of bifurcations. Therefore we have developed a method to measure the distribution of bifurcations in blood vessel by positional calibration of the ultrasound probe with the extraction of blood flow in echograms. We used a metal ball marker for calibration. The shape of blood vessels is reconstructed in a graphical interface, where three-dimensional thinning algorithm was applied. This system helps the examiner to adjust the acoustic field for ultrasound therapy using microbubbles.",
author = "Yuki Sugano and Shinya Onogi and Antoine Bossard and Takashi Mochizuki and Kohji Masuda",
year = "2012",
month = "12",
day = "1",
doi = "10.1109/BMEiCon.2012.6465483",
language = "English",
isbn = "9781467348928",
booktitle = "5th 2012 Biomedical Engineering International Conference, BMEiCON 2012",

}

TY - GEN

T1 - Development of a 3D reconstruction of blood vessel by positional calibration of ultrasound probe

AU - Sugano, Yuki

AU - Onogi, Shinya

AU - Bossard, Antoine

AU - Mochizuki, Takashi

AU - Masuda, Kohji

PY - 2012/12/1

Y1 - 2012/12/1

N2 - We have ever developed the method to realize active path selection of microbubbles at the bifurcation of blood vessel by introducing acoustic radiation force to focus the density. To apply this method to an in vivo experiment, it is necessary to understand the three-dimensional shape of blood vessel and the distribution of bifurcations. Therefore we have developed a method to measure the distribution of bifurcations in blood vessel by positional calibration of the ultrasound probe with the extraction of blood flow in echograms. We used a metal ball marker for calibration. The shape of blood vessels is reconstructed in a graphical interface, where three-dimensional thinning algorithm was applied. This system helps the examiner to adjust the acoustic field for ultrasound therapy using microbubbles.

AB - We have ever developed the method to realize active path selection of microbubbles at the bifurcation of blood vessel by introducing acoustic radiation force to focus the density. To apply this method to an in vivo experiment, it is necessary to understand the three-dimensional shape of blood vessel and the distribution of bifurcations. Therefore we have developed a method to measure the distribution of bifurcations in blood vessel by positional calibration of the ultrasound probe with the extraction of blood flow in echograms. We used a metal ball marker for calibration. The shape of blood vessels is reconstructed in a graphical interface, where three-dimensional thinning algorithm was applied. This system helps the examiner to adjust the acoustic field for ultrasound therapy using microbubbles.

UR - http://www.scopus.com/inward/record.url?scp=84875097864&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84875097864&partnerID=8YFLogxK

U2 - 10.1109/BMEiCon.2012.6465483

DO - 10.1109/BMEiCon.2012.6465483

M3 - Conference contribution

AN - SCOPUS:84875097864

SN - 9781467348928

BT - 5th 2012 Biomedical Engineering International Conference, BMEiCON 2012

ER -