Development of a gamma-ray detector with iridium transition edge sensor coupled to a pb absorber

Rathnayaka Mudiyanselage, Thushara Damayanthi, Steven W. Leman, Hiroyuki Takahashi, Masashi Ohno, Yasuhiro Minamikawa, Kentaro Nishimura, Naoko Iyomoto

研究成果: ジャーナルへの寄稿学術誌査読

7 被引用数 (Scopus)

抄録

We have recently started to develop a high-resolution gamma-ray spectrometer for material defect analysis. Our gamma-ray detector is a microcalorimeter consisting of an iridium/gold bilayer transition edge sensor (TES) thermometer and a bulk Pb absorber, which is directly coupled to a TES with Stycast 2850FT epoxy. This paper describes our TES based gamma-ray detector and the first experimental results for 662 keV and 1173 keV incident gamma-rays. We report an energy resolution of 4.7 keV at 662 keV and 2.9 keV at 1173 keV.

本文言語英語
論文番号5153084
ページ(範囲)540-543
ページ数4
ジャーナルIEEE Transactions on Applied Superconductivity
19
3
DOI
出版ステータス出版済み - 6月 2009
外部発表はい