Development of co-located 129Xe and 131Xe nuclear spin masers with external feedback scheme

T. Sato, Y. Ichikawa, S. Kojima, C. Funayama, S. Tanaka, T. Inoue, A. Uchiyama, A. Gladkov, A. Takamine, Y. Sakamoto, Y. Ohtomo, C. Hirao, M. Chikamori, E. Hikota, T. Suzuki, M. Tsuchiya, T. Furukawa, A. Yoshimi, C. P. Bidinosti, T. InoH. Ueno, Y. Matsuo, T. Fukuyama, N. Yoshinaga, Y. Sakemi, K. Asahi

研究成果: ジャーナルへの寄稿学術誌査読

11 被引用数 (Scopus)

抄録

We report on the operation of co-located 129Xe and 131Xe nuclear spin masers with an external feedback scheme, and discuss the use of 131Xe as a comagnetometer in measurements of the 129Xe spin precession frequency. By applying a correction based on the observed change in the 131Xe frequency, the frequency instability due to magnetic field and cell temperature drifts are eliminated by two orders of magnitude. The frequency precision of 6.2 μHz is obtained for a 104 s averaging time, suggesting the possibility of future improvement to ≈ 1 nHz by improving the signal-to-noise ratio of the observation.

本文言語英語
ページ(範囲)588-594
ページ数7
ジャーナルPhysics Letters, Section A: General, Atomic and Solid State Physics
382
8
DOI
出版ステータス出版済み - 2月 27 2018