Development of rapid oral bacteria detection apparatus based on dielectrophoretic impedance measurement method

R. Hamada, Junya Suehiro, Michihiko Nakano, T. Kikutani, K. Konishi

研究成果: ジャーナルへの寄稿記事

34 引用 (Scopus)

抄録

In this study, a bacteria detection apparatus based on dielectrophoretic impedance measurement (DEPIM) method was demonstrated for rapid evaluation of oral hygiene. The authors integrated a micro electrode chip on which bacteria were captured by dielectrophoresis (DEP), an AC voltage source to induce DEP force, and an impedance measurement circuit to a portable instrument that enables rapid and automated oral bacterial inspection in hospitals and clinics. Special considerations have been made on effects of high electrical conductivity of oral samples on DEP force and DEPIM results. It was shown experimentally and theoretically that using a higher electric field frequency for the DEP bacteria trap and the impedance measurement could realise DEPIM application to bacteria inspection from oral samples with higher conductivity. Based on these investigations, the authors optimised the frequency condition of the DEPIM suitable for inspecting an oral sample along with the design and development of a portable DEPIM apparatus for on-site inspection of oral bacteria. Under the optimised frequency condition, DEPIM results were in good agreement with the conventional culture method showing significant applicability of the DEPIM apparatus for practical rapid oral bacteria inspection.

元の言語英語
ページ(範囲)25-31
ページ数7
ジャーナルIET Nanobiotechnology
5
発行部数2
DOI
出版物ステータス出版済み - 6 1 2011

Fingerprint

Electric Impedance
Bacteria
Electrophoresis
Inspection
Electric Conductivity
Oral Hygiene
Electrodes
Electric fields
Networks (circuits)
Electric potential

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Biotechnology
  • Electrical and Electronic Engineering

これを引用

Development of rapid oral bacteria detection apparatus based on dielectrophoretic impedance measurement method. / Hamada, R.; Suehiro, Junya; Nakano, Michihiko; Kikutani, T.; Konishi, K.

:: IET Nanobiotechnology, 巻 5, 番号 2, 01.06.2011, p. 25-31.

研究成果: ジャーナルへの寄稿記事

@article{c7f43b4e909f4584bf21d30da683bd09,
title = "Development of rapid oral bacteria detection apparatus based on dielectrophoretic impedance measurement method",
abstract = "In this study, a bacteria detection apparatus based on dielectrophoretic impedance measurement (DEPIM) method was demonstrated for rapid evaluation of oral hygiene. The authors integrated a micro electrode chip on which bacteria were captured by dielectrophoresis (DEP), an AC voltage source to induce DEP force, and an impedance measurement circuit to a portable instrument that enables rapid and automated oral bacterial inspection in hospitals and clinics. Special considerations have been made on effects of high electrical conductivity of oral samples on DEP force and DEPIM results. It was shown experimentally and theoretically that using a higher electric field frequency for the DEP bacteria trap and the impedance measurement could realise DEPIM application to bacteria inspection from oral samples with higher conductivity. Based on these investigations, the authors optimised the frequency condition of the DEPIM suitable for inspecting an oral sample along with the design and development of a portable DEPIM apparatus for on-site inspection of oral bacteria. Under the optimised frequency condition, DEPIM results were in good agreement with the conventional culture method showing significant applicability of the DEPIM apparatus for practical rapid oral bacteria inspection.",
author = "R. Hamada and Junya Suehiro and Michihiko Nakano and T. Kikutani and K. Konishi",
year = "2011",
month = "6",
day = "1",
doi = "10.1049/iet-nbt.2010.0011",
language = "English",
volume = "5",
pages = "25--31",
journal = "IET Nanobiotechnology",
issn = "1751-8741",
publisher = "Institution of Engineering and Technology",
number = "2",

}

TY - JOUR

T1 - Development of rapid oral bacteria detection apparatus based on dielectrophoretic impedance measurement method

AU - Hamada, R.

AU - Suehiro, Junya

AU - Nakano, Michihiko

AU - Kikutani, T.

AU - Konishi, K.

PY - 2011/6/1

Y1 - 2011/6/1

N2 - In this study, a bacteria detection apparatus based on dielectrophoretic impedance measurement (DEPIM) method was demonstrated for rapid evaluation of oral hygiene. The authors integrated a micro electrode chip on which bacteria were captured by dielectrophoresis (DEP), an AC voltage source to induce DEP force, and an impedance measurement circuit to a portable instrument that enables rapid and automated oral bacterial inspection in hospitals and clinics. Special considerations have been made on effects of high electrical conductivity of oral samples on DEP force and DEPIM results. It was shown experimentally and theoretically that using a higher electric field frequency for the DEP bacteria trap and the impedance measurement could realise DEPIM application to bacteria inspection from oral samples with higher conductivity. Based on these investigations, the authors optimised the frequency condition of the DEPIM suitable for inspecting an oral sample along with the design and development of a portable DEPIM apparatus for on-site inspection of oral bacteria. Under the optimised frequency condition, DEPIM results were in good agreement with the conventional culture method showing significant applicability of the DEPIM apparatus for practical rapid oral bacteria inspection.

AB - In this study, a bacteria detection apparatus based on dielectrophoretic impedance measurement (DEPIM) method was demonstrated for rapid evaluation of oral hygiene. The authors integrated a micro electrode chip on which bacteria were captured by dielectrophoresis (DEP), an AC voltage source to induce DEP force, and an impedance measurement circuit to a portable instrument that enables rapid and automated oral bacterial inspection in hospitals and clinics. Special considerations have been made on effects of high electrical conductivity of oral samples on DEP force and DEPIM results. It was shown experimentally and theoretically that using a higher electric field frequency for the DEP bacteria trap and the impedance measurement could realise DEPIM application to bacteria inspection from oral samples with higher conductivity. Based on these investigations, the authors optimised the frequency condition of the DEPIM suitable for inspecting an oral sample along with the design and development of a portable DEPIM apparatus for on-site inspection of oral bacteria. Under the optimised frequency condition, DEPIM results were in good agreement with the conventional culture method showing significant applicability of the DEPIM apparatus for practical rapid oral bacteria inspection.

UR - http://www.scopus.com/inward/record.url?scp=79959852465&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79959852465&partnerID=8YFLogxK

U2 - 10.1049/iet-nbt.2010.0011

DO - 10.1049/iet-nbt.2010.0011

M3 - Article

C2 - 21495776

AN - SCOPUS:79959852465

VL - 5

SP - 25

EP - 31

JO - IET Nanobiotechnology

JF - IET Nanobiotechnology

SN - 1751-8741

IS - 2

ER -