Development of the equation of state for HCFO-1224yd(Z)

Detailed and extensive evaluation of the current equation and outlook for a new equation

Ryo Akasaka, Yukihiro Higashi, Shigeru Koyama

研究成果: ジャーナルへの寄稿Conference article

1 引用 (Scopus)

抄録

The first fundamental equation of state for HCFO-1224yd(Z) was published in 2017. This equation shows reasonable accuracies in the density and vapor pressure at moderate temperatures and pressures. In addition, this equation is designed to exhibit physically correct behavior in extrapolated regions. At high temperatures and pressures, however, uncertainties in calculated properties would be higher, because at this time available experimental data are limited to restricted ranges. This paper demonstrates comparisons of the current equation to some available experimental data and evaluates behavior of the equation in the extrapolated regions.

元の言語英語
ページ(範囲)218-223
ページ数6
ジャーナルRefrigeration Science and Technology
Part F147651
DOI
出版物ステータス出版済み - 1 1 2018
イベント1st IIR International Conference on the Application of HFO Refrigerants, HFO 2018 - Birmingham, 英国
継続期間: 9 2 20189 5 2018

Fingerprint

Equations of state
equations of state
evaluation
Vapor pressure
Temperature
vapor pressure
temperature
Uncertainty

All Science Journal Classification (ASJC) codes

  • Control and Systems Engineering
  • Electrical and Electronic Engineering
  • Mechanical Engineering
  • Condensed Matter Physics

これを引用

Development of the equation of state for HCFO-1224yd(Z) : Detailed and extensive evaluation of the current equation and outlook for a new equation. / Akasaka, Ryo; Higashi, Yukihiro; Koyama, Shigeru.

:: Refrigeration Science and Technology, 巻 Part F147651, 01.01.2018, p. 218-223.

研究成果: ジャーナルへの寄稿Conference article

@article{fddf24f430fb40099fe669f19d0b309e,
title = "Development of the equation of state for HCFO-1224yd(Z): Detailed and extensive evaluation of the current equation and outlook for a new equation",
abstract = "The first fundamental equation of state for HCFO-1224yd(Z) was published in 2017. This equation shows reasonable accuracies in the density and vapor pressure at moderate temperatures and pressures. In addition, this equation is designed to exhibit physically correct behavior in extrapolated regions. At high temperatures and pressures, however, uncertainties in calculated properties would be higher, because at this time available experimental data are limited to restricted ranges. This paper demonstrates comparisons of the current equation to some available experimental data and evaluates behavior of the equation in the extrapolated regions.",
author = "Ryo Akasaka and Yukihiro Higashi and Shigeru Koyama",
year = "2018",
month = "1",
day = "1",
doi = "10.18462/iir.hfo.2018.1133",
language = "English",
volume = "Part F147651",
pages = "218--223",
journal = "Refrigeration Science and Technology",
issn = "0151-1637",

}

TY - JOUR

T1 - Development of the equation of state for HCFO-1224yd(Z)

T2 - Detailed and extensive evaluation of the current equation and outlook for a new equation

AU - Akasaka, Ryo

AU - Higashi, Yukihiro

AU - Koyama, Shigeru

PY - 2018/1/1

Y1 - 2018/1/1

N2 - The first fundamental equation of state for HCFO-1224yd(Z) was published in 2017. This equation shows reasonable accuracies in the density and vapor pressure at moderate temperatures and pressures. In addition, this equation is designed to exhibit physically correct behavior in extrapolated regions. At high temperatures and pressures, however, uncertainties in calculated properties would be higher, because at this time available experimental data are limited to restricted ranges. This paper demonstrates comparisons of the current equation to some available experimental data and evaluates behavior of the equation in the extrapolated regions.

AB - The first fundamental equation of state for HCFO-1224yd(Z) was published in 2017. This equation shows reasonable accuracies in the density and vapor pressure at moderate temperatures and pressures. In addition, this equation is designed to exhibit physically correct behavior in extrapolated regions. At high temperatures and pressures, however, uncertainties in calculated properties would be higher, because at this time available experimental data are limited to restricted ranges. This paper demonstrates comparisons of the current equation to some available experimental data and evaluates behavior of the equation in the extrapolated regions.

UR - http://www.scopus.com/inward/record.url?scp=85062033570&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85062033570&partnerID=8YFLogxK

U2 - 10.18462/iir.hfo.2018.1133

DO - 10.18462/iir.hfo.2018.1133

M3 - Conference article

VL - Part F147651

SP - 218

EP - 223

JO - Refrigeration Science and Technology

JF - Refrigeration Science and Technology

SN - 0151-1637

ER -