TY - JOUR
T1 - Discriminant and simultaneous HPLC analysis of reducing and nonreducing monosaccharides on a polyethyleneimine-attached hydrophilic interaction liquid chromatography column
AU - Chung, Hsuan
AU - Shimura, Akihiro
AU - Matsui, Toshiro
PY - 2018/1/1
Y1 - 2018/1/1
N2 - The aim of this study was to develop an analytical method for the discrimination of reducing and non-reducing monosaccharides including rare sugars on a prototype hydrophilic interaction liquid chromatography (HILIC) column. The HILIC column was composed of a glycidyl methacrylate-ethylene glycol dimethacrylate copolymer attached to 8 wt% polyethyleneimine. Seven monosaccharides (reducing aldoses: D-xylose, D-allose, and D-glucose; non-reducing ketoses: D-fructose, D-psicose, D-sorbose, and D-tagatose) were targeted. In individual HPLC analysis of both aldoses and ketoses, elution with 90 v/v% acetonitrile permitted successful detection and separation only for the non-reducing ketoses. Besides, elution of a mixture of ketoses and aldoses with 85 v/v% acetonitrile containing 5 mmol/L sodium 1-octanesulfonate (OS) (pH 4.8) enabled the simultaneous separation of all seven monosaccharides within 40 min. The polyethyleneimine-attached HILIC column allowed discriminant HPLC analysis for non-reducing ketoses using elution with 90 v/v% acetonitrile, whereas elution with 85 v/v% acetonitrile containing 5 mmol/L OS simultaneously detected both ketoses and aldoses.
AB - The aim of this study was to develop an analytical method for the discrimination of reducing and non-reducing monosaccharides including rare sugars on a prototype hydrophilic interaction liquid chromatography (HILIC) column. The HILIC column was composed of a glycidyl methacrylate-ethylene glycol dimethacrylate copolymer attached to 8 wt% polyethyleneimine. Seven monosaccharides (reducing aldoses: D-xylose, D-allose, and D-glucose; non-reducing ketoses: D-fructose, D-psicose, D-sorbose, and D-tagatose) were targeted. In individual HPLC analysis of both aldoses and ketoses, elution with 90 v/v% acetonitrile permitted successful detection and separation only for the non-reducing ketoses. Besides, elution of a mixture of ketoses and aldoses with 85 v/v% acetonitrile containing 5 mmol/L sodium 1-octanesulfonate (OS) (pH 4.8) enabled the simultaneous separation of all seven monosaccharides within 40 min. The polyethyleneimine-attached HILIC column allowed discriminant HPLC analysis for non-reducing ketoses using elution with 90 v/v% acetonitrile, whereas elution with 85 v/v% acetonitrile containing 5 mmol/L OS simultaneously detected both ketoses and aldoses.
UR - http://www.scopus.com/inward/record.url?scp=85055779921&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85055779921&partnerID=8YFLogxK
U2 - 10.3136/fstr.24.501
DO - 10.3136/fstr.24.501
M3 - Article
AN - SCOPUS:85055779921
SN - 1344-6606
VL - 24
SP - 501
EP - 508
JO - Food Science and Technology Research
JF - Food Science and Technology Research
IS - 3
ER -