Eddy current testing utilizing cooled normal pickup coil and superconducting quantum interference device picovoltmeter

Tong Qing Yang, Kenichiro Yao, Daisuke Yamasaki, Keiji Enpuku

研究成果: Contribution to journalArticle査読

3 被引用数 (Scopus)

抄録

An eddy current probe utilizing a cooled normal pickup coil and a high-Tc superconducting quantum interference device (SQUID) picovoltmeter was developed. The pickup coil could be moved in an unshielded environment, during which the signal voltage across the pickup coil was transferred to the SQUID picovoltmeter, which was fixed in a cylindrical magnetic shield. By moving the pickup coil, we successfully detected a small crack on the back surface of a Cu plate in the unshielded environment. The dependences of the detected signal on the excitation frequency and thickness of the Cu plate were clarified. The frequency dependence could be used to estimate the depth of the crack from the surface of the Cu plate.

本文言語英語
ページ(範囲)L1128-L1130
ジャーナルJapanese Journal of Applied Physics, Part 2: Letters
44
33-36
DOI
出版ステータス出版済み - 8 26 2005

All Science Journal Classification (ASJC) codes

  • 工学(全般)
  • 物理学および天文学(その他)
  • 物理学および天文学(全般)

フィンガープリント

「Eddy current testing utilizing cooled normal pickup coil and superconducting quantum interference device picovoltmeter」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル