Effect of fluoride concentration and pH on corrosion behavior of titanium for dental use

M. Nakagawa, S. Matsuya, T. Shiraishi, M. Ohta

研究成果: ジャーナルへの寄稿学術誌査読

276 被引用数 (Scopus)

抄録

Titanium is used as a metal for biocompatible materials such as dental implants or restorations because of its excellent chemical stability. However, the corrosion of Ti in the prophylactic fluoride-containing environment can become problematic. To clarify the effects of fluoride concentration and pH on the corrosion behavior of Ti, we conducted anodic polarization and immersion tests in NaF solution of various concentrations and pH values. The concentrations of dissolved Ti in the test solutions were analyzed by inductively coupled plasma mass spectroscopy. There were obvious limits of fluoride concentration and the pH value at which the corrosion behavior of Ti changed. The corrosion of Ti in the solution containing fluoride depended on the concentration of hydrofluoric acid (HF). When the HF concentration in the solution was higher than about 30 ppm, the passivation film of the Ti was destroyed. The results of this study revealed a relation between the fluoride concentrations and pH values at which Ti corrosion occurred and provided data on such corrosion in environments where the fluoride concentration and pH value are known.

本文言語英語
ページ(範囲)1568-1572
ページ数5
ジャーナルJournal of Dental Research
78
9
DOI
出版ステータス出版済み - 1999

!!!All Science Journal Classification (ASJC) codes

  • 歯科学(全般)

フィンガープリント

「Effect of fluoride concentration and pH on corrosion behavior of titanium for dental use」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル