We have proposed a "micro-beam" MEMS sensor for measuring the thermal conductivity of gases and liquids. It is a beam-shaped metallic foil sensor, approximately 10 μm in length, that is built over a trench on a silicon substrate. The principle of the measurement is to determine the thermal conductivity of a sample from the temperature rise of the sensor at a steady state, which is achieved within a millisecond. Potential application of the sensor would be gas sensors and gas chromatography, where the sensor is exposed to a gas flow. Hence the objective of the present study is to examine the effect of flow on the temperature of the sensor. A chip with a platinum sensor fabricated on its surface was embedded in a flat PVC plate and placed in the potential core of an air flow from a nozzle. The electrical resistance of the sensor was measured by a four-wire technique with heating the sensor with DC current. The results showed that the temperature rise at a given heating rate, which indicates the heat dissipating potential to the air, did not change with increasing the air velocity. It also agreed well each other irrespective of the angle of attack or the length from the leading edge. The results demonstrated that the temperature rise of the sensor was independent of the air flow, suggesting that the heat dissipation was governed only by the heat conduction to the air.

元の言語英語
DOI
出版物ステータス出版済み - 1 1 2013
イベントASME 2013 4th International Conference on Micro/Nanoscale Heat and Mass Transfer, MNHMT 2013 - Hong Kong, 中国
継続期間: 12 11 201312 14 2013

その他

その他ASME 2013 4th International Conference on Micro/Nanoscale Heat and Mass Transfer, MNHMT 2013
中国
Hong Kong
期間12/11/1312/14/13

Fingerprint

Flow of gases
Thermal conductivity
Detectors
Sensors
Temperature
Air
Thermal conductivity of gases
Thermal conductivity of liquids
Acoustic impedance
Silicon
Angle of attack
Platinum
Chemical sensors
Heating rate
Heat losses
Polyvinyl Chloride
Heat conduction
Polyvinyl chlorides
Gas chromatography
Metal foil

All Science Journal Classification (ASJC) codes

  • Fluid Flow and Transfer Processes

これを引用

Takamatsu, H., Hisada, K., Fukunaga, T., & Kurata, K. (2013). Effect of gas flow on the temperature rise of a micro-beam-type thermal conductivity detector. 論文発表場所 ASME 2013 4th International Conference on Micro/Nanoscale Heat and Mass Transfer, MNHMT 2013, Hong Kong, 中国. https://doi.org/10.1115/MNHMT2013-22076

Effect of gas flow on the temperature rise of a micro-beam-type thermal conductivity detector. / Takamatsu, Hiroshi; Hisada, Kosuke; Fukunaga, Takanobu; Kurata, Kosaku.

2013. 論文発表場所 ASME 2013 4th International Conference on Micro/Nanoscale Heat and Mass Transfer, MNHMT 2013, Hong Kong, 中国.

研究成果: 会議への寄与タイプ論文

Takamatsu, H, Hisada, K, Fukunaga, T & Kurata, K 2013, 'Effect of gas flow on the temperature rise of a micro-beam-type thermal conductivity detector' 論文発表場所 ASME 2013 4th International Conference on Micro/Nanoscale Heat and Mass Transfer, MNHMT 2013, Hong Kong, 中国, 12/11/13 - 12/14/13, . https://doi.org/10.1115/MNHMT2013-22076
Takamatsu H, Hisada K, Fukunaga T, Kurata K. Effect of gas flow on the temperature rise of a micro-beam-type thermal conductivity detector. 2013. 論文発表場所 ASME 2013 4th International Conference on Micro/Nanoscale Heat and Mass Transfer, MNHMT 2013, Hong Kong, 中国. https://doi.org/10.1115/MNHMT2013-22076
Takamatsu, Hiroshi ; Hisada, Kosuke ; Fukunaga, Takanobu ; Kurata, Kosaku. / Effect of gas flow on the temperature rise of a micro-beam-type thermal conductivity detector. 論文発表場所 ASME 2013 4th International Conference on Micro/Nanoscale Heat and Mass Transfer, MNHMT 2013, Hong Kong, 中国.
@conference{5e03179403894826b339e5103cf81b7f,
title = "Effect of gas flow on the temperature rise of a micro-beam-type thermal conductivity detector",
abstract = "We have proposed a {"}micro-beam{"} MEMS sensor for measuring the thermal conductivity of gases and liquids. It is a beam-shaped metallic foil sensor, approximately 10 μm in length, that is built over a trench on a silicon substrate. The principle of the measurement is to determine the thermal conductivity of a sample from the temperature rise of the sensor at a steady state, which is achieved within a millisecond. Potential application of the sensor would be gas sensors and gas chromatography, where the sensor is exposed to a gas flow. Hence the objective of the present study is to examine the effect of flow on the temperature of the sensor. A chip with a platinum sensor fabricated on its surface was embedded in a flat PVC plate and placed in the potential core of an air flow from a nozzle. The electrical resistance of the sensor was measured by a four-wire technique with heating the sensor with DC current. The results showed that the temperature rise at a given heating rate, which indicates the heat dissipating potential to the air, did not change with increasing the air velocity. It also agreed well each other irrespective of the angle of attack or the length from the leading edge. The results demonstrated that the temperature rise of the sensor was independent of the air flow, suggesting that the heat dissipation was governed only by the heat conduction to the air.",
author = "Hiroshi Takamatsu and Kosuke Hisada and Takanobu Fukunaga and Kosaku Kurata",
year = "2013",
month = "1",
day = "1",
doi = "10.1115/MNHMT2013-22076",
language = "English",
note = "ASME 2013 4th International Conference on Micro/Nanoscale Heat and Mass Transfer, MNHMT 2013 ; Conference date: 11-12-2013 Through 14-12-2013",

}

TY - CONF

T1 - Effect of gas flow on the temperature rise of a micro-beam-type thermal conductivity detector

AU - Takamatsu, Hiroshi

AU - Hisada, Kosuke

AU - Fukunaga, Takanobu

AU - Kurata, Kosaku

PY - 2013/1/1

Y1 - 2013/1/1

N2 - We have proposed a "micro-beam" MEMS sensor for measuring the thermal conductivity of gases and liquids. It is a beam-shaped metallic foil sensor, approximately 10 μm in length, that is built over a trench on a silicon substrate. The principle of the measurement is to determine the thermal conductivity of a sample from the temperature rise of the sensor at a steady state, which is achieved within a millisecond. Potential application of the sensor would be gas sensors and gas chromatography, where the sensor is exposed to a gas flow. Hence the objective of the present study is to examine the effect of flow on the temperature of the sensor. A chip with a platinum sensor fabricated on its surface was embedded in a flat PVC plate and placed in the potential core of an air flow from a nozzle. The electrical resistance of the sensor was measured by a four-wire technique with heating the sensor with DC current. The results showed that the temperature rise at a given heating rate, which indicates the heat dissipating potential to the air, did not change with increasing the air velocity. It also agreed well each other irrespective of the angle of attack or the length from the leading edge. The results demonstrated that the temperature rise of the sensor was independent of the air flow, suggesting that the heat dissipation was governed only by the heat conduction to the air.

AB - We have proposed a "micro-beam" MEMS sensor for measuring the thermal conductivity of gases and liquids. It is a beam-shaped metallic foil sensor, approximately 10 μm in length, that is built over a trench on a silicon substrate. The principle of the measurement is to determine the thermal conductivity of a sample from the temperature rise of the sensor at a steady state, which is achieved within a millisecond. Potential application of the sensor would be gas sensors and gas chromatography, where the sensor is exposed to a gas flow. Hence the objective of the present study is to examine the effect of flow on the temperature of the sensor. A chip with a platinum sensor fabricated on its surface was embedded in a flat PVC plate and placed in the potential core of an air flow from a nozzle. The electrical resistance of the sensor was measured by a four-wire technique with heating the sensor with DC current. The results showed that the temperature rise at a given heating rate, which indicates the heat dissipating potential to the air, did not change with increasing the air velocity. It also agreed well each other irrespective of the angle of attack or the length from the leading edge. The results demonstrated that the temperature rise of the sensor was independent of the air flow, suggesting that the heat dissipation was governed only by the heat conduction to the air.

UR - http://www.scopus.com/inward/record.url?scp=84901747211&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84901747211&partnerID=8YFLogxK

U2 - 10.1115/MNHMT2013-22076

DO - 10.1115/MNHMT2013-22076

M3 - Paper

AN - SCOPUS:84901747211

ER -