Effects of tensile test specimen thickness on elongation and deformation energy for industrial pure iron

Yuji Takeda, Chatcharit Kiattisaksri, Masatoshi Aramaki, Shinji Munetoh, Osamu Furukimi

研究成果: ジャーナルへの寄稿記事

4 引用 (Scopus)

抄録

Industrial pure iron specimens with the thickness varied from 0.2 to 2.0 mm were investigated in tensile test to examine the influences of specimen thickness on elongation and deformation energy. Conventionally, the total elongation of tensile specimen can be converted by JIS 0202-1987 formula, which is related to the tensile test specimen thickness. However, in this experiment, it was noticed that there were number of factors which led to the inaccuracy in the result. The total elongation was influenced by the stress triaxiality. According to the FEM (Finite Element Method) analysis, it showed that the stress triaxiality increased significantly with the thinner specimen, this was due to the void growth behavior, observed by SEM (Scanning Electron Microscope) under low voltage. These results revealed that voids nucleation and growth behavior influenced by the stress triaxiality were the main cause for the formula incompatibility. After the tensile test, stress-strain curve can be obtained and categorized into the uniform and local deformation. The uniform deformation energy was not depended on the specimen thickness in contrast to duplex stainless steel of previous study. On the other hand, the local deformation energy lowered with the decrease in specimen thickness as with duplex stainless steel. These results indicated that the void nucleation and growth behavior had a significant impact on the total elongation.

元の言語英語
ページ(範囲)599-606
ページ数8
ジャーナルTetsu-To-Hagane/Journal of the Iron and Steel Institute of Japan
102
発行部数10
DOI
出版物ステータス出版済み - 1 1 2016

Fingerprint

tensile tests
elongation
Elongation
Iron
iron
Stainless Steel
triaxial stresses
Nucleation
Stainless steel
voids
energy
Stress-strain curves
stainless steels
nucleation
Electron microscopes
incompatibility
Scanning
Finite element method
Electric potential
low voltage

All Science Journal Classification (ASJC) codes

  • Condensed Matter Physics
  • Physical and Theoretical Chemistry
  • Metals and Alloys
  • Materials Chemistry

これを引用

Effects of tensile test specimen thickness on elongation and deformation energy for industrial pure iron. / Takeda, Yuji; Kiattisaksri, Chatcharit; Aramaki, Masatoshi; Munetoh, Shinji; Furukimi, Osamu.

:: Tetsu-To-Hagane/Journal of the Iron and Steel Institute of Japan, 巻 102, 番号 10, 01.01.2016, p. 599-606.

研究成果: ジャーナルへの寄稿記事

@article{8256c79dca7b463b95b2f00eb2d7a671,
title = "Effects of tensile test specimen thickness on elongation and deformation energy for industrial pure iron",
abstract = "Industrial pure iron specimens with the thickness varied from 0.2 to 2.0 mm were investigated in tensile test to examine the influences of specimen thickness on elongation and deformation energy. Conventionally, the total elongation of tensile specimen can be converted by JIS 0202-1987 formula, which is related to the tensile test specimen thickness. However, in this experiment, it was noticed that there were number of factors which led to the inaccuracy in the result. The total elongation was influenced by the stress triaxiality. According to the FEM (Finite Element Method) analysis, it showed that the stress triaxiality increased significantly with the thinner specimen, this was due to the void growth behavior, observed by SEM (Scanning Electron Microscope) under low voltage. These results revealed that voids nucleation and growth behavior influenced by the stress triaxiality were the main cause for the formula incompatibility. After the tensile test, stress-strain curve can be obtained and categorized into the uniform and local deformation. The uniform deformation energy was not depended on the specimen thickness in contrast to duplex stainless steel of previous study. On the other hand, the local deformation energy lowered with the decrease in specimen thickness as with duplex stainless steel. These results indicated that the void nucleation and growth behavior had a significant impact on the total elongation.",
author = "Yuji Takeda and Chatcharit Kiattisaksri and Masatoshi Aramaki and Shinji Munetoh and Osamu Furukimi",
year = "2016",
month = "1",
day = "1",
doi = "10.2355/tetsutohagane.TETSU-2016-015",
language = "English",
volume = "102",
pages = "599--606",
journal = "Tetsu-To-Hagane/Journal of the Iron and Steel Institute of Japan",
issn = "0021-1575",
publisher = "一般社団法人 日本鉄鋼協会",
number = "10",

}

TY - JOUR

T1 - Effects of tensile test specimen thickness on elongation and deformation energy for industrial pure iron

AU - Takeda, Yuji

AU - Kiattisaksri, Chatcharit

AU - Aramaki, Masatoshi

AU - Munetoh, Shinji

AU - Furukimi, Osamu

PY - 2016/1/1

Y1 - 2016/1/1

N2 - Industrial pure iron specimens with the thickness varied from 0.2 to 2.0 mm were investigated in tensile test to examine the influences of specimen thickness on elongation and deformation energy. Conventionally, the total elongation of tensile specimen can be converted by JIS 0202-1987 formula, which is related to the tensile test specimen thickness. However, in this experiment, it was noticed that there were number of factors which led to the inaccuracy in the result. The total elongation was influenced by the stress triaxiality. According to the FEM (Finite Element Method) analysis, it showed that the stress triaxiality increased significantly with the thinner specimen, this was due to the void growth behavior, observed by SEM (Scanning Electron Microscope) under low voltage. These results revealed that voids nucleation and growth behavior influenced by the stress triaxiality were the main cause for the formula incompatibility. After the tensile test, stress-strain curve can be obtained and categorized into the uniform and local deformation. The uniform deformation energy was not depended on the specimen thickness in contrast to duplex stainless steel of previous study. On the other hand, the local deformation energy lowered with the decrease in specimen thickness as with duplex stainless steel. These results indicated that the void nucleation and growth behavior had a significant impact on the total elongation.

AB - Industrial pure iron specimens with the thickness varied from 0.2 to 2.0 mm were investigated in tensile test to examine the influences of specimen thickness on elongation and deformation energy. Conventionally, the total elongation of tensile specimen can be converted by JIS 0202-1987 formula, which is related to the tensile test specimen thickness. However, in this experiment, it was noticed that there were number of factors which led to the inaccuracy in the result. The total elongation was influenced by the stress triaxiality. According to the FEM (Finite Element Method) analysis, it showed that the stress triaxiality increased significantly with the thinner specimen, this was due to the void growth behavior, observed by SEM (Scanning Electron Microscope) under low voltage. These results revealed that voids nucleation and growth behavior influenced by the stress triaxiality were the main cause for the formula incompatibility. After the tensile test, stress-strain curve can be obtained and categorized into the uniform and local deformation. The uniform deformation energy was not depended on the specimen thickness in contrast to duplex stainless steel of previous study. On the other hand, the local deformation energy lowered with the decrease in specimen thickness as with duplex stainless steel. These results indicated that the void nucleation and growth behavior had a significant impact on the total elongation.

UR - http://www.scopus.com/inward/record.url?scp=84989827502&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84989827502&partnerID=8YFLogxK

U2 - 10.2355/tetsutohagane.TETSU-2016-015

DO - 10.2355/tetsutohagane.TETSU-2016-015

M3 - Article

AN - SCOPUS:84989827502

VL - 102

SP - 599

EP - 606

JO - Tetsu-To-Hagane/Journal of the Iron and Steel Institute of Japan

JF - Tetsu-To-Hagane/Journal of the Iron and Steel Institute of Japan

SN - 0021-1575

IS - 10

ER -