Energy efficiency improvement of electrical sterilization using oscillatory waveforms from a RLC discharging circuit

Hee Kyu Lee, Junya Suehiro, Masanori Hara, Duck Chul Lee, Myung Hwan So

研究成果: ジャーナルへの寄稿学術誌査読

5 被引用数 (Scopus)

抄録

This paper describes effects of pulsed HV waveforms on biological cell inactivation. A simple RLC circuit with various inductance values was employed to investigate the waveform effects on the electrical sterilization of Escherichia Coli. It has been found that the minimum value of cell survivability can be realized by choosing an appropriate inductance value, even when the initial energy stored in a capacitor is constant. In order to realize the higher energy efficiency than a conventional RC discharging network, circuit parameters should be determined so that amplitude and width of each pulse become larger than the critical values 15 kV/cm and 50 μs, respectively.

本文言語英語
ページ(範囲)872-874
ページ数3
ジャーナルIEEE Transactions on Dielectrics and Electrical Insulation
7
6
DOI
出版ステータス出版済み - 12月 2000