Experiments for actual performance evaluation of room air-conditioners in an experimental house: Research on performance evaluation of room air-conditioners part 1

Daisuke Sumiyoshi, Takashi Ogino, Hisashi Miura, Akinori Hosoi, Takao Sawachi

研究成果: ジャーナルへの寄稿学術誌査読

1 被引用数 (Scopus)

抄録

In this research, the experiments to measure the actual performance of room air-conditioners were performed to make appropriate evaluation method of them. Results are as follows: 1. Partial load rates of air-conditioners are very low: especially in the heating use there was a machine whose partial load rates are less than 10 % in 95% of the entire operating hours. 2. COP in actual usage situation was lower than JIS experiment result in most of machines. This tendency was conspicuously appeared in heating. 3. The evaluation approach that can evaluate the actual performance at the heating period and at the low partial load appropriately should be considered.

本文言語英語
ページ(範囲)497-505
ページ数9
ジャーナルJournal of Environmental Engineering (Japan)
78
688
DOI
出版ステータス出版済み - 6月 2013

!!!All Science Journal Classification (ASJC) codes

  • 環境工学

フィンガープリント

「Experiments for actual performance evaluation of room air-conditioners in an experimental house: Research on performance evaluation of room air-conditioners part 1」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。