TY - JOUR
T1 - Gene analysis of multiple oral bacteria by the polymerase chain reaction coupled with capillary polymer electrophoresis
AU - Liu, Chenchen
AU - Yamaguchi, Yoshinori
AU - Sekine, Shinichi
AU - Ni, Yi
AU - Li, Zhenqing
AU - Zhu, Xifang
AU - Dou, Xiaoming
N1 - Publisher Copyright:
© 2015 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
PY - 2016/3/1
Y1 - 2016/3/1
N2 - Capillary polymer electrophoresis is identified as a promising technology for the analysis of DNA from bacteria, virus and cell samples. In this paper, we propose an innovative capillary polymer electrophoresis protocol for the quantification of polymerase chain reaction products. The internal standard method was modified and applied to capillary polymer electrophoresis. The precision of our modified internal standard protocol was evaluated by measuring the relative standard deviation of intermediate capillary polymer electrophoresis experiments. Results showed that the relative standard deviation was reduced from 12.4-15.1 to 0.6-2.3%. Linear regression tests were also implemented to validate our protocol. The modified internal standard method showed good linearity and robust properties. Finally, the ease of our method was illustrated by analyzing a real clinical oral sample using a one-run capillary polymer electrophoresis experiment.
AB - Capillary polymer electrophoresis is identified as a promising technology for the analysis of DNA from bacteria, virus and cell samples. In this paper, we propose an innovative capillary polymer electrophoresis protocol for the quantification of polymerase chain reaction products. The internal standard method was modified and applied to capillary polymer electrophoresis. The precision of our modified internal standard protocol was evaluated by measuring the relative standard deviation of intermediate capillary polymer electrophoresis experiments. Results showed that the relative standard deviation was reduced from 12.4-15.1 to 0.6-2.3%. Linear regression tests were also implemented to validate our protocol. The modified internal standard method showed good linearity and robust properties. Finally, the ease of our method was illustrated by analyzing a real clinical oral sample using a one-run capillary polymer electrophoresis experiment.
UR - http://www.scopus.com/inward/record.url?scp=84954461342&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84954461342&partnerID=8YFLogxK
U2 - 10.1002/jssc.201501087
DO - 10.1002/jssc.201501087
M3 - Article
C2 - 26648455
AN - SCOPUS:84954461342
SN - 1615-9306
VL - 39
SP - 986
EP - 992
JO - Journal of Separation Science
JF - Journal of Separation Science
IS - 5
ER -