Geometry effect of preloading probe on accurate needle insertion for breast tumor treatment

Maya Hatano, Yo Kobayashi, Makiko Suzuki, Yasuyuki Shiraishi, Tomoyuki Yambe, Makoto Hashizume, Masakatsu G. Fujie

研究成果: 著書/レポートタイプへの貢献会議での発言

5 引用 (Scopus)

抄録

We herein describe a needle insertion method involving tissue preloading for accurate breast tumor treatment. A mechanical preloading probe locates a tumor lesion from ultrasound imaging information and reduces lesion displacement during needle insertion by pressing the breast tissue. We validated the insertion accuracy of this method by numerical simulation and experiments both in vitro and in vivo. For further accuracy enhancement, we evaluated the geometry effect of the preloading probe on needle insertion accuracy by experiments in vitro. We compared the insertion accuracy between insertion with preloading using different probe diameters and normal needle insertion. In addition, we compared insertion accuracy at different tumor depths. The data indicated a tendency for adaptation of larger preloading probe diameters with deeper tumors. This suggests the potential for our method to enhance placement accuracy by real-time geometry regulation.

元の言語英語
ホスト出版物のタイトル2012 IEEE International Conference on Robotics and Automation, ICRA 2012
出版者Institute of Electrical and Electronics Engineers Inc.
ページ1933-1938
ページ数6
ISBN(印刷物)9781467314039
DOI
出版物ステータス出版済み - 1 1 2012
イベント 2012 IEEE International Conference on Robotics and Automation, ICRA 2012 - Saint Paul, MN, 米国
継続期間: 5 14 20125 18 2012

出版物シリーズ

名前Proceedings - IEEE International Conference on Robotics and Automation
ISSN(印刷物)1050-4729

その他

その他 2012 IEEE International Conference on Robotics and Automation, ICRA 2012
米国
Saint Paul, MN
期間5/14/125/18/12

Fingerprint

Needles
Tumors
Geometry
Tissue
Ultrasonics
Experiments
Imaging techniques
Computer simulation

All Science Journal Classification (ASJC) codes

  • Software
  • Control and Systems Engineering
  • Artificial Intelligence
  • Electrical and Electronic Engineering

これを引用

Hatano, M., Kobayashi, Y., Suzuki, M., Shiraishi, Y., Yambe, T., Hashizume, M., & Fujie, M. G. (2012). Geometry effect of preloading probe on accurate needle insertion for breast tumor treatment. : 2012 IEEE International Conference on Robotics and Automation, ICRA 2012 (pp. 1933-1938). [6224604] (Proceedings - IEEE International Conference on Robotics and Automation). Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/ICRA.2012.6224604

Geometry effect of preloading probe on accurate needle insertion for breast tumor treatment. / Hatano, Maya; Kobayashi, Yo; Suzuki, Makiko; Shiraishi, Yasuyuki; Yambe, Tomoyuki; Hashizume, Makoto; Fujie, Masakatsu G.

2012 IEEE International Conference on Robotics and Automation, ICRA 2012. Institute of Electrical and Electronics Engineers Inc., 2012. p. 1933-1938 6224604 (Proceedings - IEEE International Conference on Robotics and Automation).

研究成果: 著書/レポートタイプへの貢献会議での発言

Hatano, M, Kobayashi, Y, Suzuki, M, Shiraishi, Y, Yambe, T, Hashizume, M & Fujie, MG 2012, Geometry effect of preloading probe on accurate needle insertion for breast tumor treatment. : 2012 IEEE International Conference on Robotics and Automation, ICRA 2012., 6224604, Proceedings - IEEE International Conference on Robotics and Automation, Institute of Electrical and Electronics Engineers Inc., pp. 1933-1938, 2012 IEEE International Conference on Robotics and Automation, ICRA 2012, Saint Paul, MN, 米国, 5/14/12. https://doi.org/10.1109/ICRA.2012.6224604
Hatano M, Kobayashi Y, Suzuki M, Shiraishi Y, Yambe T, Hashizume M その他. Geometry effect of preloading probe on accurate needle insertion for breast tumor treatment. : 2012 IEEE International Conference on Robotics and Automation, ICRA 2012. Institute of Electrical and Electronics Engineers Inc. 2012. p. 1933-1938. 6224604. (Proceedings - IEEE International Conference on Robotics and Automation). https://doi.org/10.1109/ICRA.2012.6224604
Hatano, Maya ; Kobayashi, Yo ; Suzuki, Makiko ; Shiraishi, Yasuyuki ; Yambe, Tomoyuki ; Hashizume, Makoto ; Fujie, Masakatsu G. / Geometry effect of preloading probe on accurate needle insertion for breast tumor treatment. 2012 IEEE International Conference on Robotics and Automation, ICRA 2012. Institute of Electrical and Electronics Engineers Inc., 2012. pp. 1933-1938 (Proceedings - IEEE International Conference on Robotics and Automation).
@inproceedings{d6dc5a3d669b47ad94c0fde4843fe3cd,
title = "Geometry effect of preloading probe on accurate needle insertion for breast tumor treatment",
abstract = "We herein describe a needle insertion method involving tissue preloading for accurate breast tumor treatment. A mechanical preloading probe locates a tumor lesion from ultrasound imaging information and reduces lesion displacement during needle insertion by pressing the breast tissue. We validated the insertion accuracy of this method by numerical simulation and experiments both in vitro and in vivo. For further accuracy enhancement, we evaluated the geometry effect of the preloading probe on needle insertion accuracy by experiments in vitro. We compared the insertion accuracy between insertion with preloading using different probe diameters and normal needle insertion. In addition, we compared insertion accuracy at different tumor depths. The data indicated a tendency for adaptation of larger preloading probe diameters with deeper tumors. This suggests the potential for our method to enhance placement accuracy by real-time geometry regulation.",
author = "Maya Hatano and Yo Kobayashi and Makiko Suzuki and Yasuyuki Shiraishi and Tomoyuki Yambe and Makoto Hashizume and Fujie, {Masakatsu G.}",
year = "2012",
month = "1",
day = "1",
doi = "10.1109/ICRA.2012.6224604",
language = "English",
isbn = "9781467314039",
series = "Proceedings - IEEE International Conference on Robotics and Automation",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
pages = "1933--1938",
booktitle = "2012 IEEE International Conference on Robotics and Automation, ICRA 2012",
address = "United States",

}

TY - GEN

T1 - Geometry effect of preloading probe on accurate needle insertion for breast tumor treatment

AU - Hatano, Maya

AU - Kobayashi, Yo

AU - Suzuki, Makiko

AU - Shiraishi, Yasuyuki

AU - Yambe, Tomoyuki

AU - Hashizume, Makoto

AU - Fujie, Masakatsu G.

PY - 2012/1/1

Y1 - 2012/1/1

N2 - We herein describe a needle insertion method involving tissue preloading for accurate breast tumor treatment. A mechanical preloading probe locates a tumor lesion from ultrasound imaging information and reduces lesion displacement during needle insertion by pressing the breast tissue. We validated the insertion accuracy of this method by numerical simulation and experiments both in vitro and in vivo. For further accuracy enhancement, we evaluated the geometry effect of the preloading probe on needle insertion accuracy by experiments in vitro. We compared the insertion accuracy between insertion with preloading using different probe diameters and normal needle insertion. In addition, we compared insertion accuracy at different tumor depths. The data indicated a tendency for adaptation of larger preloading probe diameters with deeper tumors. This suggests the potential for our method to enhance placement accuracy by real-time geometry regulation.

AB - We herein describe a needle insertion method involving tissue preloading for accurate breast tumor treatment. A mechanical preloading probe locates a tumor lesion from ultrasound imaging information and reduces lesion displacement during needle insertion by pressing the breast tissue. We validated the insertion accuracy of this method by numerical simulation and experiments both in vitro and in vivo. For further accuracy enhancement, we evaluated the geometry effect of the preloading probe on needle insertion accuracy by experiments in vitro. We compared the insertion accuracy between insertion with preloading using different probe diameters and normal needle insertion. In addition, we compared insertion accuracy at different tumor depths. The data indicated a tendency for adaptation of larger preloading probe diameters with deeper tumors. This suggests the potential for our method to enhance placement accuracy by real-time geometry regulation.

UR - http://www.scopus.com/inward/record.url?scp=84864489962&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84864489962&partnerID=8YFLogxK

U2 - 10.1109/ICRA.2012.6224604

DO - 10.1109/ICRA.2012.6224604

M3 - Conference contribution

AN - SCOPUS:84864489962

SN - 9781467314039

T3 - Proceedings - IEEE International Conference on Robotics and Automation

SP - 1933

EP - 1938

BT - 2012 IEEE International Conference on Robotics and Automation, ICRA 2012

PB - Institute of Electrical and Electronics Engineers Inc.

ER -