TY - JOUR
T1 - Histological comparison of three apatitic bone substitutes with different carbonate contents in alveolar bone defects in a beagle mandible with simultaneous implant installation
AU - Mano, Takamitsu
AU - Akita, Kazuya
AU - Fukuda, Naoyuki
AU - Kamada, Kumiko
AU - Kurio, Naito
AU - Ishikawa, Kunio
AU - Miyamoto, Youji
N1 - Funding Information:
This animal experiment was, in part, funded by GC Corporation. However, GC Corporation had no further participation in conducting of the study, and exerted no control over the interpretation, authoring, or publication of the results of this work.
Funding Information:
This research was supported by Japan Agency for Medical Research and Development under Grant Number JP18im0502004.
PY - 2020/5/1
Y1 - 2020/5/1
N2 - Since bone apatite is a carbonate apatite containing carbonate in an apatitic structure, carbonate content may be one of the factors governing the osteoconductivity of apatitic bone substitutes. The aim of this study was to evaluate the effects of carbonate content on the osteoconductivity of apatitic bone substitutes using three commercially available bone substitutes for the reconstruction of alveolar bone defects of a beagle mandible with simultaneous dental implant installation. NEOBONE, Bio-Oss, and Cytrans that contain 0.1, 5.5, and 12.0 mass% of carbonate, respectively, were used in this study. The amount of newly formed bone in the upper portion of the alveolar bone defect of the beagle's mandible was 0.7, 6.6, and 39.4% at 4 weeks after surgery and 4.7, 39.5, and 75.2% at 12 weeks after surgery for NEOBONE, Bio-Oss, and Cytrans, respectively. The results indicate that bone-to-implant contact ratio was the largest for Cytrans. Additionally, the continuity of the alveolar ridge was restored in the case of Cytrans, whereas the continuity of the alveolar ridge was not sufficient when using NEOBONE and Bio-Oss. Both Cytrans and Bio-Oss that have a relatively larger carbonate content in their apatitic structure was resorbed with time. We concluded that carbonate content is one of important factors governing the osteoconductivity of apatitic bone substitutes.
AB - Since bone apatite is a carbonate apatite containing carbonate in an apatitic structure, carbonate content may be one of the factors governing the osteoconductivity of apatitic bone substitutes. The aim of this study was to evaluate the effects of carbonate content on the osteoconductivity of apatitic bone substitutes using three commercially available bone substitutes for the reconstruction of alveolar bone defects of a beagle mandible with simultaneous dental implant installation. NEOBONE, Bio-Oss, and Cytrans that contain 0.1, 5.5, and 12.0 mass% of carbonate, respectively, were used in this study. The amount of newly formed bone in the upper portion of the alveolar bone defect of the beagle's mandible was 0.7, 6.6, and 39.4% at 4 weeks after surgery and 4.7, 39.5, and 75.2% at 12 weeks after surgery for NEOBONE, Bio-Oss, and Cytrans, respectively. The results indicate that bone-to-implant contact ratio was the largest for Cytrans. Additionally, the continuity of the alveolar ridge was restored in the case of Cytrans, whereas the continuity of the alveolar ridge was not sufficient when using NEOBONE and Bio-Oss. Both Cytrans and Bio-Oss that have a relatively larger carbonate content in their apatitic structure was resorbed with time. We concluded that carbonate content is one of important factors governing the osteoconductivity of apatitic bone substitutes.
UR - http://www.scopus.com/inward/record.url?scp=85074255508&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85074255508&partnerID=8YFLogxK
U2 - 10.1002/jbm.b.34492
DO - 10.1002/jbm.b.34492
M3 - Article
C2 - 31622016
AN - SCOPUS:85074255508
SN - 1552-4973
VL - 108
SP - 1450
EP - 1459
JO - Journal of Biomedical Materials Research - Part B Applied Biomaterials
JF - Journal of Biomedical Materials Research - Part B Applied Biomaterials
IS - 4
ER -