Homeostatic capability of rate-sensitive feedback system: Mathematical model

M. Okamoto, K. Hayashi

研究成果: ジャーナルへの寄稿記事

4 引用 (Scopus)

抄録

We have predicted the mathematical model of rat-sensitive feedback control system and have investigated its homeostatic capability by using computer simulations. The results are summarized as follows. 1) By installing a cyclic enzyme system as feedback control element, we could assume the rate-sensitive feedback system at molecular level. 2) This type of feedback had realistic constant-value control capability for external perturbations. 3) This feedback system was more effective for the exclusion of perturbation than was the concentration-sensitive feedback. 4) A large-loop feedback was more stable for perturbation than was short-loop feedback. 5) In sequential feedback system, every key enzyme sensitive to feedback control had to vary the activity at same time for the system to keep homeostasis.

元の言語英語
ジャーナルAmerican Journal of Physiology - Regulatory Integrative and Comparative Physiology
16
発行部数5
出版物ステータス出版済み - 1 1 1984

Fingerprint

Theoretical Models
Enzymes
Computer Simulation
Homeostasis

All Science Journal Classification (ASJC) codes

  • Physiology
  • Physiology (medical)

これを引用

Homeostatic capability of rate-sensitive feedback system : Mathematical model. / Okamoto, M.; Hayashi, K.

:: American Journal of Physiology - Regulatory Integrative and Comparative Physiology, 巻 16, 番号 5, 01.01.1984.

研究成果: ジャーナルへの寄稿記事

@article{020110139710482cbaae505d541234e9,
title = "Homeostatic capability of rate-sensitive feedback system: Mathematical model",
abstract = "We have predicted the mathematical model of rat-sensitive feedback control system and have investigated its homeostatic capability by using computer simulations. The results are summarized as follows. 1) By installing a cyclic enzyme system as feedback control element, we could assume the rate-sensitive feedback system at molecular level. 2) This type of feedback had realistic constant-value control capability for external perturbations. 3) This feedback system was more effective for the exclusion of perturbation than was the concentration-sensitive feedback. 4) A large-loop feedback was more stable for perturbation than was short-loop feedback. 5) In sequential feedback system, every key enzyme sensitive to feedback control had to vary the activity at same time for the system to keep homeostasis.",
author = "M. Okamoto and K. Hayashi",
year = "1984",
month = "1",
day = "1",
language = "English",
volume = "16",
journal = "American Journal of Physiology",
issn = "0363-6119",
publisher = "American Physiological Society",
number = "5",

}

TY - JOUR

T1 - Homeostatic capability of rate-sensitive feedback system

T2 - Mathematical model

AU - Okamoto, M.

AU - Hayashi, K.

PY - 1984/1/1

Y1 - 1984/1/1

N2 - We have predicted the mathematical model of rat-sensitive feedback control system and have investigated its homeostatic capability by using computer simulations. The results are summarized as follows. 1) By installing a cyclic enzyme system as feedback control element, we could assume the rate-sensitive feedback system at molecular level. 2) This type of feedback had realistic constant-value control capability for external perturbations. 3) This feedback system was more effective for the exclusion of perturbation than was the concentration-sensitive feedback. 4) A large-loop feedback was more stable for perturbation than was short-loop feedback. 5) In sequential feedback system, every key enzyme sensitive to feedback control had to vary the activity at same time for the system to keep homeostasis.

AB - We have predicted the mathematical model of rat-sensitive feedback control system and have investigated its homeostatic capability by using computer simulations. The results are summarized as follows. 1) By installing a cyclic enzyme system as feedback control element, we could assume the rate-sensitive feedback system at molecular level. 2) This type of feedback had realistic constant-value control capability for external perturbations. 3) This feedback system was more effective for the exclusion of perturbation than was the concentration-sensitive feedback. 4) A large-loop feedback was more stable for perturbation than was short-loop feedback. 5) In sequential feedback system, every key enzyme sensitive to feedback control had to vary the activity at same time for the system to keep homeostasis.

UR - http://www.scopus.com/inward/record.url?scp=19244369144&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=19244369144&partnerID=8YFLogxK

M3 - Article

C2 - 6496776

AN - SCOPUS:19244369144

VL - 16

JO - American Journal of Physiology

JF - American Journal of Physiology

SN - 0363-6119

IS - 5

ER -