抄録
The influence of hydrogen entry on ductility was evaluated in a ternary twinning-induced plasticity (TWIP) steel with a composition of Fe-18Mn-0.6C in wt.% using tensile tests. The samples with a thickness of 1.2. mm were charged with hydrogen galvanostatically during the tensile tests. Significant hydrogen content was introduced by the hydrogen-charging. The total elongation was significantly deteriorated from approx. 60% to 30% by the hydrogen-charging. A clear intergranular fracture surface was observed in a vicinity of the sample surface in the hydrogen-charged samples.
本文言語 | 英語 |
---|---|
ページ(範囲) | 1-4 |
ページ数 | 4 |
ジャーナル | Corrosion Science |
巻 | 54 |
号 | 1 |
DOI | |
出版ステータス | 出版済み - 1月 2012 |
外部発表 | はい |
!!!All Science Journal Classification (ASJC) codes
- 化学 (全般)
- 化学工学(全般)
- 材料科学(全般)