Hydrogen pump-type impurity sensors for hydrogen fuels

Z. Noda, K. Hirata, A. Hayashi, T. Takahashi, N. Nakazato, K. Saigusa, A. Seo, K. Suzuki, S. Ariura, H. Shinkai, K. Sasaki

研究成果: Contribution to journalArticle査読

4 被引用数 (Scopus)

抄録

A hydrogen pump-type hydrogen sensor cell has been developed for continuously detecting a trace amount of impurities contained in hydrogen fuels, by using the impurity poisoning effect of PEFC-type electrochemical cells. The impurity-sensitive sensor cell was produced by extremely reducing Pt catalyst loading in order to detect even a small amount of impurities. This type of sensors with the stable baseline can detect major hydrogen fuel impurities, CO, H2S, and NH3, with the ppm-level detection limit.

本文言語英語
ページ(範囲)3281-3293
ページ数13
ジャーナルInternational Journal of Hydrogen Energy
42
5
DOI
出版ステータス出版済み - 2 2 2017

All Science Journal Classification (ASJC) codes

  • 再生可能エネルギー、持続可能性、環境
  • 燃料技術
  • 凝縮系物理学
  • エネルギー工学および電力技術