Impact of biomimetic diamond-like carbon coated titanium on osteoblast and osteoclast differentiation in vitro

Yuichi Mine, Tatsuyuki Nakatani, Keishi Okamoto, Shintarou Hara, Kentaro Takagi, Hiroki Nikawa

    研究成果: Contribution to journalArticle査読

    6 被引用数 (Scopus)

    抄録

    To examine the effects of hydrogen amount-altered biomimetic DLC film, osteoblastic MC3T3-E1 cells and osteoclastic RAW264.7 cells were cultured on titanium (Ti) disks coated with or without DLC including various amount of hydrogen. The amount of hydrogen in DLC film is reduced from 20.9% to 0.8%. Real-time quantitative reverse transcriptase-polymerase chain reaction analysis showed that typeⅠcollagen mRNA in MC3T3-E1 cells cultured on specific hydrogen-containing DLC coated Ti disks was significantly higher than those of control Ti disks. In addition, specific hydrogen-containing DLC coated Ti disks significantly inhibited the expression of TRAP mRNA in RANKL-treated RAW264.7 cells. These results, taken together, suggested that biomimetic DLC altered osteoblast and osteoclast differentiation, which could promise long-term success of implant therapy.