Two types of Planecta™ ports are commonly used as sampling ports in blood pressure transducer kits: a flat-type port (FTP) and a port with a three-way stopcock (PTS). Recently, a new type of three-way stopcock (Marvelous™) has been released as a Planecta™ counterpart, but its effects on the frequency characteristics and reliability of blood pressure monitoring have not been investigated. We assessed the influence of the Marvelous™ stopcock on the frequency characteristics of the pressure transducer kit. The basic pressure transducer kit, DT4812J, was modified by replacing one or two of the original three-way stopcocks with Marvelous™ stopcocks. The frequency characteristics (i.e., natural frequency and damping coefficient) of each kit were determined using wave parameter analysis software, and subsequently evaluated on a Gardner chart. Replacement of the original blood pressure transducer kit stopcocks with Marvelous™ stopcocks decreased the natural frequency (48.3 Hz) to 46.3 Hz or 44.8 Hz, respectively; the damping coefficient was not significantly changed. Plotting the data on a Gardner chart revealed that the changes fell within the adequate dynamic response region, indicating they were within the allowable range. Insertion of Marvelous™ stopcocks slightly affects the natural frequency of the pressure transducer kit, similar to inserting a PTS. The results indicate that the Marvelous™ stopcock is useful for accurate monitoring of arterial blood pressure, and may be recommended when insertion of two or more closed-loop blood sampling systems is necessary.

元の言語英語
ページ(範囲)63-72
ページ数10
ジャーナルJournal of Clinical Monitoring and Computing
32
発行部数1
DOI
出版物ステータス出版済み - 2 1 2018

Fingerprint

Pressure Transducers
Blood Pressure
Arterial Pressure
Software

All Science Journal Classification (ASJC) codes

  • Health Informatics
  • Critical Care and Intensive Care Medicine
  • Anesthesiology and Pain Medicine

これを引用

Influence of the marvelous™ three-way stopcock on the natural frequency and damping coefficient in blood pressure transducer kits. / Fujiwara, Shigeki Joseph Luke; Tachihara, Keiichi; Mori, Satoshi; Ouchi, Kentaro; Itakura, Shoko; Yasuda, Michiko; Hitosugi, Takashi; Imaizumi, Uno; Miki, Yoichiro; Toyoguchi, Izumi; Yoshida, Kazu ichi; Yokoyama, Takeshi.

:: Journal of Clinical Monitoring and Computing, 巻 32, 番号 1, 01.02.2018, p. 63-72.

研究成果: ジャーナルへの寄稿記事

Fujiwara, Shigeki Joseph Luke ; Tachihara, Keiichi ; Mori, Satoshi ; Ouchi, Kentaro ; Itakura, Shoko ; Yasuda, Michiko ; Hitosugi, Takashi ; Imaizumi, Uno ; Miki, Yoichiro ; Toyoguchi, Izumi ; Yoshida, Kazu ichi ; Yokoyama, Takeshi. / Influence of the marvelous™ three-way stopcock on the natural frequency and damping coefficient in blood pressure transducer kits. :: Journal of Clinical Monitoring and Computing. 2018 ; 巻 32, 番号 1. pp. 63-72.
@article{18a3158f9a9d4447ab9282b4eacae190,
title = "Influence of the marvelous™ three-way stopcock on the natural frequency and damping coefficient in blood pressure transducer kits",
abstract = "Two types of Planecta™ ports are commonly used as sampling ports in blood pressure transducer kits: a flat-type port (FTP) and a port with a three-way stopcock (PTS). Recently, a new type of three-way stopcock (Marvelous™) has been released as a Planecta™ counterpart, but its effects on the frequency characteristics and reliability of blood pressure monitoring have not been investigated. We assessed the influence of the Marvelous™ stopcock on the frequency characteristics of the pressure transducer kit. The basic pressure transducer kit, DT4812J, was modified by replacing one or two of the original three-way stopcocks with Marvelous™ stopcocks. The frequency characteristics (i.e., natural frequency and damping coefficient) of each kit were determined using wave parameter analysis software, and subsequently evaluated on a Gardner chart. Replacement of the original blood pressure transducer kit stopcocks with Marvelous™ stopcocks decreased the natural frequency (48.3 Hz) to 46.3 Hz or 44.8 Hz, respectively; the damping coefficient was not significantly changed. Plotting the data on a Gardner chart revealed that the changes fell within the adequate dynamic response region, indicating they were within the allowable range. Insertion of Marvelous™ stopcocks slightly affects the natural frequency of the pressure transducer kit, similar to inserting a PTS. The results indicate that the Marvelous™ stopcock is useful for accurate monitoring of arterial blood pressure, and may be recommended when insertion of two or more closed-loop blood sampling systems is necessary.",
author = "Fujiwara, {Shigeki Joseph Luke} and Keiichi Tachihara and Satoshi Mori and Kentaro Ouchi and Shoko Itakura and Michiko Yasuda and Takashi Hitosugi and Uno Imaizumi and Yoichiro Miki and Izumi Toyoguchi and Yoshida, {Kazu ichi} and Takeshi Yokoyama",
year = "2018",
month = "2",
day = "1",
doi = "10.1007/s10877-017-9979-0",
language = "English",
volume = "32",
pages = "63--72",
journal = "Journal of Clinical Monitoring and Computing",
issn = "1387-1307",
publisher = "Springer Netherlands",
number = "1",

}

TY - JOUR

T1 - Influence of the marvelous™ three-way stopcock on the natural frequency and damping coefficient in blood pressure transducer kits

AU - Fujiwara, Shigeki Joseph Luke

AU - Tachihara, Keiichi

AU - Mori, Satoshi

AU - Ouchi, Kentaro

AU - Itakura, Shoko

AU - Yasuda, Michiko

AU - Hitosugi, Takashi

AU - Imaizumi, Uno

AU - Miki, Yoichiro

AU - Toyoguchi, Izumi

AU - Yoshida, Kazu ichi

AU - Yokoyama, Takeshi

PY - 2018/2/1

Y1 - 2018/2/1

N2 - Two types of Planecta™ ports are commonly used as sampling ports in blood pressure transducer kits: a flat-type port (FTP) and a port with a three-way stopcock (PTS). Recently, a new type of three-way stopcock (Marvelous™) has been released as a Planecta™ counterpart, but its effects on the frequency characteristics and reliability of blood pressure monitoring have not been investigated. We assessed the influence of the Marvelous™ stopcock on the frequency characteristics of the pressure transducer kit. The basic pressure transducer kit, DT4812J, was modified by replacing one or two of the original three-way stopcocks with Marvelous™ stopcocks. The frequency characteristics (i.e., natural frequency and damping coefficient) of each kit were determined using wave parameter analysis software, and subsequently evaluated on a Gardner chart. Replacement of the original blood pressure transducer kit stopcocks with Marvelous™ stopcocks decreased the natural frequency (48.3 Hz) to 46.3 Hz or 44.8 Hz, respectively; the damping coefficient was not significantly changed. Plotting the data on a Gardner chart revealed that the changes fell within the adequate dynamic response region, indicating they were within the allowable range. Insertion of Marvelous™ stopcocks slightly affects the natural frequency of the pressure transducer kit, similar to inserting a PTS. The results indicate that the Marvelous™ stopcock is useful for accurate monitoring of arterial blood pressure, and may be recommended when insertion of two or more closed-loop blood sampling systems is necessary.

AB - Two types of Planecta™ ports are commonly used as sampling ports in blood pressure transducer kits: a flat-type port (FTP) and a port with a three-way stopcock (PTS). Recently, a new type of three-way stopcock (Marvelous™) has been released as a Planecta™ counterpart, but its effects on the frequency characteristics and reliability of blood pressure monitoring have not been investigated. We assessed the influence of the Marvelous™ stopcock on the frequency characteristics of the pressure transducer kit. The basic pressure transducer kit, DT4812J, was modified by replacing one or two of the original three-way stopcocks with Marvelous™ stopcocks. The frequency characteristics (i.e., natural frequency and damping coefficient) of each kit were determined using wave parameter analysis software, and subsequently evaluated on a Gardner chart. Replacement of the original blood pressure transducer kit stopcocks with Marvelous™ stopcocks decreased the natural frequency (48.3 Hz) to 46.3 Hz or 44.8 Hz, respectively; the damping coefficient was not significantly changed. Plotting the data on a Gardner chart revealed that the changes fell within the adequate dynamic response region, indicating they were within the allowable range. Insertion of Marvelous™ stopcocks slightly affects the natural frequency of the pressure transducer kit, similar to inserting a PTS. The results indicate that the Marvelous™ stopcock is useful for accurate monitoring of arterial blood pressure, and may be recommended when insertion of two or more closed-loop blood sampling systems is necessary.

UR - http://www.scopus.com/inward/record.url?scp=85009165563&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85009165563&partnerID=8YFLogxK

U2 - 10.1007/s10877-017-9979-0

DO - 10.1007/s10877-017-9979-0

M3 - Article

VL - 32

SP - 63

EP - 72

JO - Journal of Clinical Monitoring and Computing

JF - Journal of Clinical Monitoring and Computing

SN - 1387-1307

IS - 1

ER -