Instability in kiloamp class a.c. superconducting cables

K. Funaki, M. Nakashima, M. Iwakuma, M. Takeo, K. Yamafuji

研究成果: Contribution to journalArticle査読

18 被引用数 (Scopus)

抄録

In kiloamp (kA) class superconducting cables for a.c. use, where each strand does not have an insulation layer, the quench current in 60 Hz operation was found to be no more than 50% of the d.c. critical current, even on the load line. The degradation in the 60 Hz quench current of the kA class cables is discussed with respect to: 1, an a.c. instability in the multifilamentary wire; 2, magnetic coupling among strands in concentric multistrand cables; 3, the influence of local disorder in cabling on current distribution; and 4, the temperature rise due to steady a.c. losses. While points 2 and 3 induce non-uniform current distribution, points 1 and 4 were found to be factors in the reduction of quench current in the strands with higher current density. Some local overheatings may also contribute to the intense degradation.

本文言語英語
ページ(範囲)594-597
ページ数4
ジャーナルCryogenics
31
7
DOI
出版ステータス出版済み - 7 1991

All Science Journal Classification (ASJC) codes

  • 材料科学(全般)
  • 物理学および天文学(全般)

フィンガープリント

「Instability in kiloamp class a.c. superconducting cables」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。