[Inter-laboratory crosscheck study of dioxins and PCBs in human blood samples].

Jumboku Kajiwara, Takashi Todaka, Hironori Hirakawa, Tsuguhide Hori, Daisuke Yasutake, Takashi Miyawaki, Kazuhiro Tobiishi, Yoshiko Takao, Teruaki Hirata, Hiroshi Uchi, Masutaka Furue

研究成果: ジャーナルへの寄稿記事

抄録

We developed an analytical method for accurately determining the concentrations of dioxin and polychlorinated biphenyls(PCBs) in a blood volume of 5 g. Inter-laboratory crosscheck is available for maintaining the quality of dioxin and PCB analysis. We carried out the crosschecks of dioxin and PCB analysis in the blood with domestic analysis organizations. Two crosschecks each of dioxin and PCB analysis were carried out from 2007 through 2011. As a result, the findings of our analysis accorded well with the analyses of the other organizations. We believe that our analytical method is sufficiently reliable.

元の言語英語
ページ(範囲)104-109
ページ数6
ジャーナルUnknown Journal
104
発行部数4
出版物ステータス出版済み - 1 1 2013
外部発表Yes

Fingerprint

Dioxins
Polychlorinated Biphenyls
Blood Volume

All Science Journal Classification (ASJC) codes

  • Medicine(all)

これを引用

Kajiwara, J., Todaka, T., Hirakawa, H., Hori, T., Yasutake, D., Miyawaki, T., ... Furue, M. (2013). [Inter-laboratory crosscheck study of dioxins and PCBs in human blood samples]. Unknown Journal, 104(4), 104-109.

[Inter-laboratory crosscheck study of dioxins and PCBs in human blood samples]. / Kajiwara, Jumboku; Todaka, Takashi; Hirakawa, Hironori; Hori, Tsuguhide; Yasutake, Daisuke; Miyawaki, Takashi; Tobiishi, Kazuhiro; Takao, Yoshiko; Hirata, Teruaki; Uchi, Hiroshi; Furue, Masutaka.

:: Unknown Journal, 巻 104, 番号 4, 01.01.2013, p. 104-109.

研究成果: ジャーナルへの寄稿記事

Kajiwara, J, Todaka, T, Hirakawa, H, Hori, T, Yasutake, D, Miyawaki, T, Tobiishi, K, Takao, Y, Hirata, T, Uchi, H & Furue, M 2013, '[Inter-laboratory crosscheck study of dioxins and PCBs in human blood samples].', Unknown Journal, 巻. 104, 番号 4, pp. 104-109.
Kajiwara J, Todaka T, Hirakawa H, Hori T, Yasutake D, Miyawaki T その他. [Inter-laboratory crosscheck study of dioxins and PCBs in human blood samples]. Unknown Journal. 2013 1 1;104(4):104-109.
Kajiwara, Jumboku ; Todaka, Takashi ; Hirakawa, Hironori ; Hori, Tsuguhide ; Yasutake, Daisuke ; Miyawaki, Takashi ; Tobiishi, Kazuhiro ; Takao, Yoshiko ; Hirata, Teruaki ; Uchi, Hiroshi ; Furue, Masutaka. / [Inter-laboratory crosscheck study of dioxins and PCBs in human blood samples]. :: Unknown Journal. 2013 ; 巻 104, 番号 4. pp. 104-109.
@article{e4fe1bbeb8b04f7f9668d30cb3cb1476,
title = "[Inter-laboratory crosscheck study of dioxins and PCBs in human blood samples].",
abstract = "We developed an analytical method for accurately determining the concentrations of dioxin and polychlorinated biphenyls(PCBs) in a blood volume of 5 g. Inter-laboratory crosscheck is available for maintaining the quality of dioxin and PCB analysis. We carried out the crosschecks of dioxin and PCB analysis in the blood with domestic analysis organizations. Two crosschecks each of dioxin and PCB analysis were carried out from 2007 through 2011. As a result, the findings of our analysis accorded well with the analyses of the other organizations. We believe that our analytical method is sufficiently reliable.",
author = "Jumboku Kajiwara and Takashi Todaka and Hironori Hirakawa and Tsuguhide Hori and Daisuke Yasutake and Takashi Miyawaki and Kazuhiro Tobiishi and Yoshiko Takao and Teruaki Hirata and Hiroshi Uchi and Masutaka Furue",
year = "2013",
month = "1",
day = "1",
language = "English",
volume = "104",
pages = "104--109",
journal = "Quaternary International",
issn = "1040-6182",
publisher = "Elsevier Limited",
number = "4",

}

TY - JOUR

T1 - [Inter-laboratory crosscheck study of dioxins and PCBs in human blood samples].

AU - Kajiwara, Jumboku

AU - Todaka, Takashi

AU - Hirakawa, Hironori

AU - Hori, Tsuguhide

AU - Yasutake, Daisuke

AU - Miyawaki, Takashi

AU - Tobiishi, Kazuhiro

AU - Takao, Yoshiko

AU - Hirata, Teruaki

AU - Uchi, Hiroshi

AU - Furue, Masutaka

PY - 2013/1/1

Y1 - 2013/1/1

N2 - We developed an analytical method for accurately determining the concentrations of dioxin and polychlorinated biphenyls(PCBs) in a blood volume of 5 g. Inter-laboratory crosscheck is available for maintaining the quality of dioxin and PCB analysis. We carried out the crosschecks of dioxin and PCB analysis in the blood with domestic analysis organizations. Two crosschecks each of dioxin and PCB analysis were carried out from 2007 through 2011. As a result, the findings of our analysis accorded well with the analyses of the other organizations. We believe that our analytical method is sufficiently reliable.

AB - We developed an analytical method for accurately determining the concentrations of dioxin and polychlorinated biphenyls(PCBs) in a blood volume of 5 g. Inter-laboratory crosscheck is available for maintaining the quality of dioxin and PCB analysis. We carried out the crosschecks of dioxin and PCB analysis in the blood with domestic analysis organizations. Two crosschecks each of dioxin and PCB analysis were carried out from 2007 through 2011. As a result, the findings of our analysis accorded well with the analyses of the other organizations. We believe that our analytical method is sufficiently reliable.

UR - http://www.scopus.com/inward/record.url?scp=84886785713&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84886785713&partnerID=8YFLogxK

M3 - Article

VL - 104

SP - 104

EP - 109

JO - Quaternary International

JF - Quaternary International

SN - 1040-6182

IS - 4

ER -