Li0.4CoO2 was investigated for its applicability to a potentiometric CO2 sensor using NASICON (Na+ conductor, Na3Zr2Si2PO12) as a solid-reference counter electrode material. Compared with Na0.6CoCO2, Li0.4CoCO2 was more stable to storage at room temperature as well as to attack by CO2 at 600°C, as measured for powders or powder attached devices. When coated with a layer of glass, Li 0.4CoO2 attached-counter electrode allowed the device to generate stable EMF response to CO2 at 450 °C. These results confirm that Li0.4CoO2 can be used as a solid reference counter electrode even more reliable than Na0.6CoO2.

元の言語英語
ページ58-65
ページ数8
出版物ステータス出版済み - 2004
イベントChemical Sensors VI: Chemical and Biological Sensors and Analytical Methods - Proceedings of the International Symposium - Honolulu, HI, 米国
継続期間: 10 3 200410 8 2004

その他

その他Chemical Sensors VI: Chemical and Biological Sensors and Analytical Methods - Proceedings of the International Symposium
米国
Honolulu, HI
期間10/3/0410/8/04

All Science Journal Classification (ASJC) codes

  • Engineering(all)

フィンガープリント Investigation of counter electrode material for nasicon based potentiometric CO<sub>2</sub> sensor' の研究トピックを掘り下げます。これらはともに一意のフィンガープリントを構成します。

  • これを引用

    Miyachi, Y., Kishi, S., Shimanoe, K., & Yamazoe, N. (2004). Investigation of counter electrode material for nasicon based potentiometric CO2 sensor. 58-65. 論文発表場所 Chemical Sensors VI: Chemical and Biological Sensors and Analytical Methods - Proceedings of the International Symposium, Honolulu, HI, 米国.