Low cost humidity controlled air-conditioning system for building energy savings in tropical climate

Azizuddin Abd Aziz, Daisuke Sumiyoshi, Yasunori Akashi

研究成果: ジャーナルへの寄稿記事

6 引用 (Scopus)

抄録

The viable solution to the high latent load that naturally occurs in tropical regions requires an alternative system that runs at relatively low energy consumption yet be able to provide indoor thermal comfort by effective handling of the excessive humidity. Although the existing outdoor air treatment system is a proven approach, it is unpopular in developing countries due to its high initial cost. In this paper, a new system termed Dual Air Handling Unit system is proposed to be the answer. The function of Humidity-control Air Handling Unit is to remove the moisture from the conditioned room up to the desired humidity level and in the process the room temperature is also fractionally reduced. The Temperature-control Air Handling Unit completes the task by removing the remaining sensible heat so that the room temperature is maintained at the required set-point. By reducing the relative humidity to 50%, a much lower value than that of the normal air-conditioning could offer, room temperature of the new system is shifted higher to 26 °C in order to reduce the energy consumption. The simulation result shows that the proposed system offers energy savings up to 13.2% compared to the conventional air-conditioning system, without compromising the thermal comfort of the occupants.

元の言語英語
ページ(範囲)9-16
ページ数8
ジャーナルJournal of Building Engineering
11
DOI
出版物ステータス出版済み - 5 1 2017

Fingerprint

Air conditioning
Atmospheric humidity
Energy conservation
Thermal comfort
Air
Costs
Energy utilization
Humidity control
Developing countries
Temperature control
Temperature
Moisture

All Science Journal Classification (ASJC) codes

  • Civil and Structural Engineering
  • Architecture
  • Building and Construction
  • Safety, Risk, Reliability and Quality
  • Mechanics of Materials

これを引用

Low cost humidity controlled air-conditioning system for building energy savings in tropical climate. / Aziz, Azizuddin Abd; Sumiyoshi, Daisuke; Akashi, Yasunori.

:: Journal of Building Engineering, 巻 11, 01.05.2017, p. 9-16.

研究成果: ジャーナルへの寄稿記事

@article{886d795ac96141bc8c274696afc5e7b0,
title = "Low cost humidity controlled air-conditioning system for building energy savings in tropical climate",
abstract = "The viable solution to the high latent load that naturally occurs in tropical regions requires an alternative system that runs at relatively low energy consumption yet be able to provide indoor thermal comfort by effective handling of the excessive humidity. Although the existing outdoor air treatment system is a proven approach, it is unpopular in developing countries due to its high initial cost. In this paper, a new system termed Dual Air Handling Unit system is proposed to be the answer. The function of Humidity-control Air Handling Unit is to remove the moisture from the conditioned room up to the desired humidity level and in the process the room temperature is also fractionally reduced. The Temperature-control Air Handling Unit completes the task by removing the remaining sensible heat so that the room temperature is maintained at the required set-point. By reducing the relative humidity to 50{\%}, a much lower value than that of the normal air-conditioning could offer, room temperature of the new system is shifted higher to 26 °C in order to reduce the energy consumption. The simulation result shows that the proposed system offers energy savings up to 13.2{\%} compared to the conventional air-conditioning system, without compromising the thermal comfort of the occupants.",
author = "Aziz, {Azizuddin Abd} and Daisuke Sumiyoshi and Yasunori Akashi",
year = "2017",
month = "5",
day = "1",
doi = "10.1016/j.jobe.2017.03.005",
language = "English",
volume = "11",
pages = "9--16",
journal = "Journal of Building Engineering",
issn = "2352-7102",
publisher = "Elsevier BV",

}

TY - JOUR

T1 - Low cost humidity controlled air-conditioning system for building energy savings in tropical climate

AU - Aziz, Azizuddin Abd

AU - Sumiyoshi, Daisuke

AU - Akashi, Yasunori

PY - 2017/5/1

Y1 - 2017/5/1

N2 - The viable solution to the high latent load that naturally occurs in tropical regions requires an alternative system that runs at relatively low energy consumption yet be able to provide indoor thermal comfort by effective handling of the excessive humidity. Although the existing outdoor air treatment system is a proven approach, it is unpopular in developing countries due to its high initial cost. In this paper, a new system termed Dual Air Handling Unit system is proposed to be the answer. The function of Humidity-control Air Handling Unit is to remove the moisture from the conditioned room up to the desired humidity level and in the process the room temperature is also fractionally reduced. The Temperature-control Air Handling Unit completes the task by removing the remaining sensible heat so that the room temperature is maintained at the required set-point. By reducing the relative humidity to 50%, a much lower value than that of the normal air-conditioning could offer, room temperature of the new system is shifted higher to 26 °C in order to reduce the energy consumption. The simulation result shows that the proposed system offers energy savings up to 13.2% compared to the conventional air-conditioning system, without compromising the thermal comfort of the occupants.

AB - The viable solution to the high latent load that naturally occurs in tropical regions requires an alternative system that runs at relatively low energy consumption yet be able to provide indoor thermal comfort by effective handling of the excessive humidity. Although the existing outdoor air treatment system is a proven approach, it is unpopular in developing countries due to its high initial cost. In this paper, a new system termed Dual Air Handling Unit system is proposed to be the answer. The function of Humidity-control Air Handling Unit is to remove the moisture from the conditioned room up to the desired humidity level and in the process the room temperature is also fractionally reduced. The Temperature-control Air Handling Unit completes the task by removing the remaining sensible heat so that the room temperature is maintained at the required set-point. By reducing the relative humidity to 50%, a much lower value than that of the normal air-conditioning could offer, room temperature of the new system is shifted higher to 26 °C in order to reduce the energy consumption. The simulation result shows that the proposed system offers energy savings up to 13.2% compared to the conventional air-conditioning system, without compromising the thermal comfort of the occupants.

UR - http://www.scopus.com/inward/record.url?scp=85016026766&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85016026766&partnerID=8YFLogxK

U2 - 10.1016/j.jobe.2017.03.005

DO - 10.1016/j.jobe.2017.03.005

M3 - Article

AN - SCOPUS:85016026766

VL - 11

SP - 9

EP - 16

JO - Journal of Building Engineering

JF - Journal of Building Engineering

SN - 2352-7102

ER -