Measurements of adsorption/desorption rate of a film adsorbent synthesized on heat transfer plate controlled by adsorbent temperature in water vapor

Takafumi Ouchi, Yoshinori Hamamoto, Hideo Mori

研究成果: 著書/レポートタイプへの貢献会議での発言

抄録

Enhancement of adsorption/desorption rate in an adsorption heat exchanger is effective to enhance cooling/heating power per unit volume of adsorption chillers and dehumidifying/humidifying rate of desiccant systems. To achieve this, it is necessary to improve heat transfer performance in the adsorption heat exchanger. In the present study, for a porous alumina film adsorbent synthesized with anodization on an aluminum plate, we measured the adsorption/desorption rate in water vapor with gravimetric method using a cantilever. Consequently, the effective diffusivity in water vapor was larger than that in moist air due to the mass transfer resistance of fluid film in moist air. In water vapor, the diffusivity inside pores dominated the diffusivity and it decreased when the number of adsorption layer changes. It is supposed that a change of activation energy for adsorption/desorption due to a change of the adsorption layer number leads to the decrease of the diffusivity.

元の言語英語
ホスト出版物のタイトル24th IIR International Congress of Refrigeration, ICR 2015
出版者International Institute of Refrigeration
ページ599-606
ページ数8
ISBN(電子版)9782362150128
DOI
出版物ステータス出版済み - 1 1 2015
イベント24th IIR International Congress of Refrigeration, ICR 2015 - Yokohama, 日本
継続期間: 8 16 20158 22 2015

その他

その他24th IIR International Congress of Refrigeration, ICR 2015
日本
Yokohama
期間8/16/158/22/15

Fingerprint

Plates (structural components)
adsorbents
Adsorbents
Water vapor
water vapor
Desorption
desorption
heat transfer
Adsorption
adsorption
diffusivity
Temperature
temperature
heat exchangers
Heat exchangers
desiccants
fluid films
air
Air
mass transfer

All Science Journal Classification (ASJC) codes

  • Control and Systems Engineering
  • Electrical and Electronic Engineering
  • Mechanical Engineering
  • Condensed Matter Physics

これを引用

Ouchi, T., Hamamoto, Y., & Mori, H. (2015). Measurements of adsorption/desorption rate of a film adsorbent synthesized on heat transfer plate controlled by adsorbent temperature in water vapor. : 24th IIR International Congress of Refrigeration, ICR 2015 (pp. 599-606). International Institute of Refrigeration. https://doi.org/10.18462/iir.icr.2015.0940

Measurements of adsorption/desorption rate of a film adsorbent synthesized on heat transfer plate controlled by adsorbent temperature in water vapor. / Ouchi, Takafumi; Hamamoto, Yoshinori; Mori, Hideo.

24th IIR International Congress of Refrigeration, ICR 2015. International Institute of Refrigeration, 2015. p. 599-606.

研究成果: 著書/レポートタイプへの貢献会議での発言

Ouchi, T, Hamamoto, Y & Mori, H 2015, Measurements of adsorption/desorption rate of a film adsorbent synthesized on heat transfer plate controlled by adsorbent temperature in water vapor. : 24th IIR International Congress of Refrigeration, ICR 2015. International Institute of Refrigeration, pp. 599-606, 24th IIR International Congress of Refrigeration, ICR 2015, Yokohama, 日本, 8/16/15. https://doi.org/10.18462/iir.icr.2015.0940
Ouchi T, Hamamoto Y, Mori H. Measurements of adsorption/desorption rate of a film adsorbent synthesized on heat transfer plate controlled by adsorbent temperature in water vapor. : 24th IIR International Congress of Refrigeration, ICR 2015. International Institute of Refrigeration. 2015. p. 599-606 https://doi.org/10.18462/iir.icr.2015.0940
Ouchi, Takafumi ; Hamamoto, Yoshinori ; Mori, Hideo. / Measurements of adsorption/desorption rate of a film adsorbent synthesized on heat transfer plate controlled by adsorbent temperature in water vapor. 24th IIR International Congress of Refrigeration, ICR 2015. International Institute of Refrigeration, 2015. pp. 599-606
@inproceedings{b478027f59f84dfcab3912c52bf6cbc7,
title = "Measurements of adsorption/desorption rate of a film adsorbent synthesized on heat transfer plate controlled by adsorbent temperature in water vapor",
abstract = "Enhancement of adsorption/desorption rate in an adsorption heat exchanger is effective to enhance cooling/heating power per unit volume of adsorption chillers and dehumidifying/humidifying rate of desiccant systems. To achieve this, it is necessary to improve heat transfer performance in the adsorption heat exchanger. In the present study, for a porous alumina film adsorbent synthesized with anodization on an aluminum plate, we measured the adsorption/desorption rate in water vapor with gravimetric method using a cantilever. Consequently, the effective diffusivity in water vapor was larger than that in moist air due to the mass transfer resistance of fluid film in moist air. In water vapor, the diffusivity inside pores dominated the diffusivity and it decreased when the number of adsorption layer changes. It is supposed that a change of activation energy for adsorption/desorption due to a change of the adsorption layer number leads to the decrease of the diffusivity.",
author = "Takafumi Ouchi and Yoshinori Hamamoto and Hideo Mori",
year = "2015",
month = "1",
day = "1",
doi = "10.18462/iir.icr.2015.0940",
language = "English",
pages = "599--606",
booktitle = "24th IIR International Congress of Refrigeration, ICR 2015",
publisher = "International Institute of Refrigeration",

}

TY - GEN

T1 - Measurements of adsorption/desorption rate of a film adsorbent synthesized on heat transfer plate controlled by adsorbent temperature in water vapor

AU - Ouchi, Takafumi

AU - Hamamoto, Yoshinori

AU - Mori, Hideo

PY - 2015/1/1

Y1 - 2015/1/1

N2 - Enhancement of adsorption/desorption rate in an adsorption heat exchanger is effective to enhance cooling/heating power per unit volume of adsorption chillers and dehumidifying/humidifying rate of desiccant systems. To achieve this, it is necessary to improve heat transfer performance in the adsorption heat exchanger. In the present study, for a porous alumina film adsorbent synthesized with anodization on an aluminum plate, we measured the adsorption/desorption rate in water vapor with gravimetric method using a cantilever. Consequently, the effective diffusivity in water vapor was larger than that in moist air due to the mass transfer resistance of fluid film in moist air. In water vapor, the diffusivity inside pores dominated the diffusivity and it decreased when the number of adsorption layer changes. It is supposed that a change of activation energy for adsorption/desorption due to a change of the adsorption layer number leads to the decrease of the diffusivity.

AB - Enhancement of adsorption/desorption rate in an adsorption heat exchanger is effective to enhance cooling/heating power per unit volume of adsorption chillers and dehumidifying/humidifying rate of desiccant systems. To achieve this, it is necessary to improve heat transfer performance in the adsorption heat exchanger. In the present study, for a porous alumina film adsorbent synthesized with anodization on an aluminum plate, we measured the adsorption/desorption rate in water vapor with gravimetric method using a cantilever. Consequently, the effective diffusivity in water vapor was larger than that in moist air due to the mass transfer resistance of fluid film in moist air. In water vapor, the diffusivity inside pores dominated the diffusivity and it decreased when the number of adsorption layer changes. It is supposed that a change of activation energy for adsorption/desorption due to a change of the adsorption layer number leads to the decrease of the diffusivity.

UR - http://www.scopus.com/inward/record.url?scp=85016759377&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85016759377&partnerID=8YFLogxK

U2 - 10.18462/iir.icr.2015.0940

DO - 10.18462/iir.icr.2015.0940

M3 - Conference contribution

SP - 599

EP - 606

BT - 24th IIR International Congress of Refrigeration, ICR 2015

PB - International Institute of Refrigeration

ER -