Measurements of Saturation Pressures for Trifluoroethene (R1123) and 3,3,3-Trifluoropropene (R1243zf)

Yukihiro Higashi, Naoya Sakoda, Md Amirul Islam, Yasuyuki Takata, Shigeru Koyama, Ryo Akasaka

研究成果: ジャーナルへの寄稿記事

9 引用 (Scopus)

抄録

Saturation pressures for new low global warming potential refrigerants trifluoroethene (R1123, CF2= CHF) and 3,3,3-trifluoropropene (R1243zf, CF3CH=CH2) were measured by the isochoric method for temperatures between 278 and 377 K. Temperature was measured with a 25 standard platinum resistance thermometer on ITS-90. Pressure was measured with a digital quartz pressure transducer. The experimental uncertainties in temperature and pressure are estimated to be 5 mK and 1 kPa (k = 2), respectively. New saturation-pressure correlations for the refrigerants have been formulated based on the present saturation-pressure data. The critical pressures of R1123 and R1243zf were also determined.

元の言語英語
ページ(範囲)417-421
ページ数5
ジャーナルJournal of Chemical and Engineering Data
63
発行部数2
DOI
出版物ステータス出版済み - 2 8 2018

Fingerprint

Refrigerants
Quartz
Pressure transducers
Thermometers
Global warming
Platinum
Temperature
trifluoroethene
Uncertainty

All Science Journal Classification (ASJC) codes

  • Chemistry(all)
  • Chemical Engineering(all)

これを引用

Measurements of Saturation Pressures for Trifluoroethene (R1123) and 3,3,3-Trifluoropropene (R1243zf). / Higashi, Yukihiro; Sakoda, Naoya; Islam, Md Amirul; Takata, Yasuyuki; Koyama, Shigeru; Akasaka, Ryo.

:: Journal of Chemical and Engineering Data, 巻 63, 番号 2, 08.02.2018, p. 417-421.

研究成果: ジャーナルへの寄稿記事

@article{83730b25f17b46169f284a4a2701d3fd,
title = "Measurements of Saturation Pressures for Trifluoroethene (R1123) and 3,3,3-Trifluoropropene (R1243zf)",
abstract = "Saturation pressures for new low global warming potential refrigerants trifluoroethene (R1123, CF2= CHF) and 3,3,3-trifluoropropene (R1243zf, CF3CH=CH2) were measured by the isochoric method for temperatures between 278 and 377 K. Temperature was measured with a 25 standard platinum resistance thermometer on ITS-90. Pressure was measured with a digital quartz pressure transducer. The experimental uncertainties in temperature and pressure are estimated to be 5 mK and 1 kPa (k = 2), respectively. New saturation-pressure correlations for the refrigerants have been formulated based on the present saturation-pressure data. The critical pressures of R1123 and R1243zf were also determined.",
author = "Yukihiro Higashi and Naoya Sakoda and Islam, {Md Amirul} and Yasuyuki Takata and Shigeru Koyama and Ryo Akasaka",
year = "2018",
month = "2",
day = "8",
doi = "10.1021/acs.jced.7b00818",
language = "English",
volume = "63",
pages = "417--421",
journal = "Journal of Chemical & Engineering Data",
issn = "0021-9568",
publisher = "American Chemical Society",
number = "2",

}

TY - JOUR

T1 - Measurements of Saturation Pressures for Trifluoroethene (R1123) and 3,3,3-Trifluoropropene (R1243zf)

AU - Higashi, Yukihiro

AU - Sakoda, Naoya

AU - Islam, Md Amirul

AU - Takata, Yasuyuki

AU - Koyama, Shigeru

AU - Akasaka, Ryo

PY - 2018/2/8

Y1 - 2018/2/8

N2 - Saturation pressures for new low global warming potential refrigerants trifluoroethene (R1123, CF2= CHF) and 3,3,3-trifluoropropene (R1243zf, CF3CH=CH2) were measured by the isochoric method for temperatures between 278 and 377 K. Temperature was measured with a 25 standard platinum resistance thermometer on ITS-90. Pressure was measured with a digital quartz pressure transducer. The experimental uncertainties in temperature and pressure are estimated to be 5 mK and 1 kPa (k = 2), respectively. New saturation-pressure correlations for the refrigerants have been formulated based on the present saturation-pressure data. The critical pressures of R1123 and R1243zf were also determined.

AB - Saturation pressures for new low global warming potential refrigerants trifluoroethene (R1123, CF2= CHF) and 3,3,3-trifluoropropene (R1243zf, CF3CH=CH2) were measured by the isochoric method for temperatures between 278 and 377 K. Temperature was measured with a 25 standard platinum resistance thermometer on ITS-90. Pressure was measured with a digital quartz pressure transducer. The experimental uncertainties in temperature and pressure are estimated to be 5 mK and 1 kPa (k = 2), respectively. New saturation-pressure correlations for the refrigerants have been formulated based on the present saturation-pressure data. The critical pressures of R1123 and R1243zf were also determined.

UR - http://www.scopus.com/inward/record.url?scp=85042006277&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85042006277&partnerID=8YFLogxK

U2 - 10.1021/acs.jced.7b00818

DO - 10.1021/acs.jced.7b00818

M3 - Article

AN - SCOPUS:85042006277

VL - 63

SP - 417

EP - 421

JO - Journal of Chemical & Engineering Data

JF - Journal of Chemical & Engineering Data

SN - 0021-9568

IS - 2

ER -