Measurements of the vapor-liquid coexistence curve and the critical locus for several refrigerant mixtures

Y. Higashi, M. Uematsu, K. Watanabe

研究成果: Contribution to journalArticle査読

18 被引用数 (Scopus)

抄録

Measurements of the vapor-liquid coexistence curve in the critical region for the systems of binary refrigerant mixture, i.e., Refrigerant 22 + Refrigerant 114 and Refrigerant 13B1 + Refrigerant 114, have been made by visual observation of the meniscus at the vapor-liquid interface within an optical cell. The experimental uncertainty of the temperature, density, and mass fraction is estimated within 15 mK, 0.5%, and 0.05%, respectively. The critical locus for these mixtures has been determined taking into consideration the disappearing meniscus level and the intensity of the critical opalescence. In accordance with the previous results of the Refrigerant 12 + Refrigerant 22 system, the coexistence curve for binary refrigerant mixtures is discussed. The composition dependence of the critical parameters for refrigerant mixtures is also discussed and compared with that of several predictive methods.

本文言語英語
ページ(範囲)29-40
ページ数12
ジャーナルInternational Journal of Thermophysics
7
1
DOI
出版ステータス出版済み - 1 1986
外部発表はい

All Science Journal Classification (ASJC) codes

  • 凝縮系物理学

フィンガープリント

「Measurements of the vapor-liquid coexistence curve and the critical locus for several refrigerant mixtures」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル