Micro-isolation valve for fuel tank array

Koji Takahashi, Kunihito Nagayama, Tetsuo Yasaka, Tanemasa Asano

研究成果: 著書/レポートタイプへの貢献会議での発言

抜粋

Isolation valve system for low-cost liquid tank array is designed and demonstrated. This valve is normally closed and opens only once for liquid injection. This array system can supply precise amount of liquid at each operation as many times as the number of tanks. In order to tolerate the ambient high pressure and to accomplish the perfect injection, a large and thick membrane is fabricated and tested as valve. Without any special structure, our valves are found to open just by applying low AC voltage to a pair of electrodes that are apart from each other by tens of micrometers. Dielectric breakdown and pressure increase inside tank are found to work effectively to form a large hole.

元の言語英語
ホスト出版物のタイトルMicro-Electro-Mechanical Systems (MEMS) - 2001
編集者A.L. Lee, J. Simon, K. Breuer, S. Chen, R.S. Keynton, A. Malshe, J.-I. Mou, M. Dunn
ページ271-276
ページ数6
3
出版物ステータス出版済み - 2001
イベント2001 ASME International Mechanical Engineering Congress and Exposition - New York, NY, 米国
継続期間: 11 11 200111 16 2001

その他

その他2001 ASME International Mechanical Engineering Congress and Exposition
米国
New York, NY
期間11/11/0111/16/01

    フィンガープリント

All Science Journal Classification (ASJC) codes

  • Engineering(all)

これを引用

Takahashi, K., Nagayama, K., Yasaka, T., & Asano, T. (2001). Micro-isolation valve for fuel tank array. : A. L. Lee, J. Simon, K. Breuer, S. Chen, R. S. Keynton, A. Malshe, J-I. Mou, ... M. Dunn (版), Micro-Electro-Mechanical Systems (MEMS) - 2001 (巻 3, pp. 271-276)