T1 - Microcalorimeter-type energy dispersive X-ray spectrometer for a transmission electron microscope
AU - Hara, Toru
AU - Tanaka, Keiichi
AU - Maehata, Keisuke
AU - Mitsuda, Kazuhisa
AU - Yamasaki, Noriko Y.
AU - Ohsaki, Mitsuaki
AU - Watanabe, Katsuaki
AU - Yu, Xiuzhen
AU - Ito, Takuji
AU - Yamanaka, Yoshihiro
N1 - Funding Information:
This work has been financially supported by the Leading Project of the Ministry of Education, Sports, Science and Technology (MEXT) ‘Development of elementary techniques for electron microscope in next generation’ program.
PY - 2010/2
Y1 - 2010/2
N2 - A new energy dispersive X-ray spectrometer (EDS) with a mi- crocalorimeter detector equipped with a transmission electron microscope (TEM) has been developed for high- accuracy compositional analysis in the nanoscale. A superconducting transition-edge-sensor-type microcalorimeter is applied as the detector. A cryogen-free cooling system, which consists of a mechanical and a dilution refrigerator, is selected to achieve long-term temperature stability. In order to mount these detector and refrigerators on a TEM, the cooling system is specially designed such that these two refrigerators are separated. Also, the detector position and arrangement are carefully designed to avoid adverse affects between the superconductor detector and the TEM lens system. Using the developed EDS system, at present, an energy resolution of 21.92 eV full-width-at-half maximum has been achieved at the Cr Kα line. This value is about seven times better than that of the current typical commercial Si(Li) detector, which is usually around 140 eV. The developed microcalorimeter EDS system can measure a wide energy range, 1-20 keV, at one time with this high energy resolution that can resolve peaks from most of the elements. Although several further developments will be needed to enable practical use, highly accurate compositional analysis with high energy resolution will be realized by this microcalorimeter EDS system.
AB - A new energy dispersive X-ray spectrometer (EDS) with a mi- crocalorimeter detector equipped with a transmission electron microscope (TEM) has been developed for high- accuracy compositional analysis in the nanoscale. A superconducting transition-edge-sensor-type microcalorimeter is applied as the detector. A cryogen-free cooling system, which consists of a mechanical and a dilution refrigerator, is selected to achieve long-term temperature stability. In order to mount these detector and refrigerators on a TEM, the cooling system is specially designed such that these two refrigerators are separated. Also, the detector position and arrangement are carefully designed to avoid adverse affects between the superconductor detector and the TEM lens system. Using the developed EDS system, at present, an energy resolution of 21.92 eV full-width-at-half maximum has been achieved at the Cr Kα line. This value is about seven times better than that of the current typical commercial Si(Li) detector, which is usually around 140 eV. The developed microcalorimeter EDS system can measure a wide energy range, 1-20 keV, at one time with this high energy resolution that can resolve peaks from most of the elements. Although several further developments will be needed to enable practical use, highly accurate compositional analysis with high energy resolution will be realized by this microcalorimeter EDS system.
UR - http://www.scopus.com/inward/record.url?scp=76649092320&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=76649092320&partnerID=8YFLogxK
U2 - 10.1093/jmicro/dfp043
DO - 10.1093/jmicro/dfp043
M3 - Article
C2 - 19717388
AN - SCOPUS:76649092320
VL - 59
SP - 17
EP - 26
JO - Microscopy (Oxford, England)
JF - Microscopy (Oxford, England)
SN - 2050-5698
IS - 1
ER -