Molecules with a one octave frequency domain for the measurement of the 1-fs optical pulse width

Tomoko Imasaka, Totaro Imasaka

研究成果: 著書/レポートタイプへの貢献会議での発言

抄録

Tetraazacrown was useful for measuring a >1.6-fs pulse in the ultraviolet region and aliphatic hydrocarbon for a >0.96-fs pulse in the far-ultraviolet region using an autocorrelator consisting of a mass spectrometer as a two-photon-response detector.

元の言語英語
ホスト出版物のタイトルCLEO: Applications and Technology, CLEO_AT 2012
出版物ステータス出版済み - 2012
イベントCLEO: Applications and Technology, CLEO_AT 2012 - San Jose, CA, 米国
継続期間: 5 6 20125 11 2012

その他

その他CLEO: Applications and Technology, CLEO_AT 2012
米国
San Jose, CA
期間5/6/125/11/12

Fingerprint

Mass spectrometers
Hydrocarbons
Laser pulses
Photons
Detectors
Molecules

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials

これを引用

Imasaka, T., & Imasaka, T. (2012). Molecules with a one octave frequency domain for the measurement of the 1-fs optical pulse width. : CLEO: Applications and Technology, CLEO_AT 2012

Molecules with a one octave frequency domain for the measurement of the 1-fs optical pulse width. / Imasaka, Tomoko; Imasaka, Totaro.

CLEO: Applications and Technology, CLEO_AT 2012. 2012.

研究成果: 著書/レポートタイプへの貢献会議での発言

Imasaka, T & Imasaka, T 2012, Molecules with a one octave frequency domain for the measurement of the 1-fs optical pulse width. : CLEO: Applications and Technology, CLEO_AT 2012. CLEO: Applications and Technology, CLEO_AT 2012, San Jose, CA, 米国, 5/6/12.
Imasaka T, Imasaka T. Molecules with a one octave frequency domain for the measurement of the 1-fs optical pulse width. : CLEO: Applications and Technology, CLEO_AT 2012. 2012
Imasaka, Tomoko ; Imasaka, Totaro. / Molecules with a one octave frequency domain for the measurement of the 1-fs optical pulse width. CLEO: Applications and Technology, CLEO_AT 2012. 2012.
@inproceedings{fcbb66d9048849cb921b06fe9ea50b14,
title = "Molecules with a one octave frequency domain for the measurement of the 1-fs optical pulse width",
abstract = "Tetraazacrown was useful for measuring a >1.6-fs pulse in the ultraviolet region and aliphatic hydrocarbon for a >0.96-fs pulse in the far-ultraviolet region using an autocorrelator consisting of a mass spectrometer as a two-photon-response detector.",
author = "Tomoko Imasaka and Totaro Imasaka",
year = "2012",
language = "English",
isbn = "9781557529435",
booktitle = "CLEO: Applications and Technology, CLEO_AT 2012",

}

TY - GEN

T1 - Molecules with a one octave frequency domain for the measurement of the 1-fs optical pulse width

AU - Imasaka, Tomoko

AU - Imasaka, Totaro

PY - 2012

Y1 - 2012

N2 - Tetraazacrown was useful for measuring a >1.6-fs pulse in the ultraviolet region and aliphatic hydrocarbon for a >0.96-fs pulse in the far-ultraviolet region using an autocorrelator consisting of a mass spectrometer as a two-photon-response detector.

AB - Tetraazacrown was useful for measuring a >1.6-fs pulse in the ultraviolet region and aliphatic hydrocarbon for a >0.96-fs pulse in the far-ultraviolet region using an autocorrelator consisting of a mass spectrometer as a two-photon-response detector.