NUCLEATE BOILING HEAT TRANSFER IN VERTICAL NARROW SPACE.

Y. Fujita, H. Ohta, S. Uchida

研究成果: 会議への寄与タイプ論文

5 引用 (Scopus)

抄録

Pool boiling heat transfer in confined space is systematically investigated for vertical narrow space between parallel flat planes, one of which is heated and the other is unheated. Experiments for water at atmospheric pressure are performed at heat flux range up to the critical on heating surfaces with width of 30mm, and heights of 30 and 120mm, and gap sizes of 5. 0. 2. 0, 0. 6, and 0. 15mm. Periphery of heating surface is open in one experiment, and closed at the bottom and the sides in another experiment. Based on the observation and measurements, the general behavior of boiling characteristics, and the heat transfer mechanisms and models are presented and discussed.

元の言語英語
ページ469-476
ページ数8
出版物ステータス出版済み - 1 1 1987

Fingerprint

Nucleate boiling
Heat transfer
Boiling liquids
Heating
Experiments
Atmospheric pressure
Heat flux
Water

All Science Journal Classification (ASJC) codes

  • Engineering(all)

これを引用

Fujita, Y., Ohta, H., & Uchida, S. (1987). NUCLEATE BOILING HEAT TRANSFER IN VERTICAL NARROW SPACE.. 469-476.

NUCLEATE BOILING HEAT TRANSFER IN VERTICAL NARROW SPACE. / Fujita, Y.; Ohta, H.; Uchida, S.

1987. 469-476.

研究成果: 会議への寄与タイプ論文

Fujita, Y, Ohta, H & Uchida, S 1987, 'NUCLEATE BOILING HEAT TRANSFER IN VERTICAL NARROW SPACE.', pp. 469-476.
Fujita, Y. ; Ohta, H. ; Uchida, S. / NUCLEATE BOILING HEAT TRANSFER IN VERTICAL NARROW SPACE. 8 p.
@conference{9a9c0273fcd04ce2a71638c3baffa268,
title = "NUCLEATE BOILING HEAT TRANSFER IN VERTICAL NARROW SPACE.",
abstract = "Pool boiling heat transfer in confined space is systematically investigated for vertical narrow space between parallel flat planes, one of which is heated and the other is unheated. Experiments for water at atmospheric pressure are performed at heat flux range up to the critical on heating surfaces with width of 30mm, and heights of 30 and 120mm, and gap sizes of 5. 0. 2. 0, 0. 6, and 0. 15mm. Periphery of heating surface is open in one experiment, and closed at the bottom and the sides in another experiment. Based on the observation and measurements, the general behavior of boiling characteristics, and the heat transfer mechanisms and models are presented and discussed.",
author = "Y. Fujita and H. Ohta and S. Uchida",
year = "1987",
month = "1",
day = "1",
language = "English",
pages = "469--476",

}

TY - CONF

T1 - NUCLEATE BOILING HEAT TRANSFER IN VERTICAL NARROW SPACE.

AU - Fujita, Y.

AU - Ohta, H.

AU - Uchida, S.

PY - 1987/1/1

Y1 - 1987/1/1

N2 - Pool boiling heat transfer in confined space is systematically investigated for vertical narrow space between parallel flat planes, one of which is heated and the other is unheated. Experiments for water at atmospheric pressure are performed at heat flux range up to the critical on heating surfaces with width of 30mm, and heights of 30 and 120mm, and gap sizes of 5. 0. 2. 0, 0. 6, and 0. 15mm. Periphery of heating surface is open in one experiment, and closed at the bottom and the sides in another experiment. Based on the observation and measurements, the general behavior of boiling characteristics, and the heat transfer mechanisms and models are presented and discussed.

AB - Pool boiling heat transfer in confined space is systematically investigated for vertical narrow space between parallel flat planes, one of which is heated and the other is unheated. Experiments for water at atmospheric pressure are performed at heat flux range up to the critical on heating surfaces with width of 30mm, and heights of 30 and 120mm, and gap sizes of 5. 0. 2. 0, 0. 6, and 0. 15mm. Periphery of heating surface is open in one experiment, and closed at the bottom and the sides in another experiment. Based on the observation and measurements, the general behavior of boiling characteristics, and the heat transfer mechanisms and models are presented and discussed.

UR - http://www.scopus.com/inward/record.url?scp=0023268319&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0023268319&partnerID=8YFLogxK

M3 - Paper

AN - SCOPUS:0023268319

SP - 469

EP - 476

ER -