On-line evaluation of spatial dose-distribution by using a 15m-long plastic scintillation-fiber detector

A. Nohtomi, N. Sugiura, T. Itoh, T. Torii

研究成果: Chapter in Book/Report/Conference proceedingConference contribution

6 被引用数 (Scopus)

抄録

A 15m-long plastic scintillation fiber (PSF) detector has been applied to the on-line evaluation of spatial dose-distribution inside radiation facilities. The aim of this study is to realize the real-time measurement system which is not only simple but also reliable for monitoring use. Determination of radiation-incident points was made by the measurement of time difference that two directional signals of the scintillation light reach both ends of the PSF [so called "time-of-flight (TOF) method"]. The PSF used had practically enough sensitivity to detect both fast neutrons and gamma-rays.

本文言語英語
ホスト出版物のタイトル2008 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2008
ページ965-968
ページ数4
DOI
出版ステータス出版済み - 12 1 2008
外部発表はい
イベント2008 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2008 - Dresden, ドイツ
継続期間: 10 19 200810 25 2008

出版物シリーズ

名前IEEE Nuclear Science Symposium Conference Record
ISSN(印刷版)1095-7863

その他

その他2008 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2008
Countryドイツ
CityDresden
Period10/19/0810/25/08

All Science Journal Classification (ASJC) codes

  • Radiation
  • Nuclear and High Energy Physics
  • Radiology Nuclear Medicine and imaging