Optimal Frequency of Low-Frequency Eddy-Current Testing for Detecting Defects on the Backside of Thick Steel Plates

Wataru Yoshimura, Teruyoshi Sasayama, Keiji Enpuku

研究成果: ジャーナルへの寄稿記事

抄録

Defect detection on the backside of thick steel plates is essential for the safety maintenance of most infrastructures in which they are used. Eddy-current testing (ECT) is a promising method to detect the defects in a steel plate, and inspections at low frequencies are necessary to suppress the skin effect. However, if the frequency is reduced further, the signal from the detection coil also becomes smaller. Therefore, we assessed the optimal frequency for the detection of slit defects on the backside of a 10 mm thick steel plate based on experiments and electromagnetic simulations using the finite-element method. The results suggest that the optimal frequency to detect the defects is approximately 8-10 Hz when the height of the slit exceeds 6 mm. Similarly, in the simulation, the signal was maximized when the frequency was 8-10 Hz, which validates the experimental results. Furthermore, we propose a method to emphasize the deeper defects using multi-frequency data as a fundamental study. The results show that the backside defects are depicted more clearly.

元の言語英語
記事番号8645817
ジャーナルIEEE Transactions on Magnetics
55
発行部数7
DOI
出版物ステータス出版済み - 7 1 2019

Fingerprint

Eddy current testing
Steel
Defects
Skin effect
Inspection
Finite element method
Experiments

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Electrical and Electronic Engineering

これを引用

Optimal Frequency of Low-Frequency Eddy-Current Testing for Detecting Defects on the Backside of Thick Steel Plates. / Yoshimura, Wataru; Sasayama, Teruyoshi; Enpuku, Keiji.

:: IEEE Transactions on Magnetics, 巻 55, 番号 7, 8645817, 01.07.2019.

研究成果: ジャーナルへの寄稿記事

@article{82c686d8bfaf4e07885d624645a686c0,
title = "Optimal Frequency of Low-Frequency Eddy-Current Testing for Detecting Defects on the Backside of Thick Steel Plates",
abstract = "Defect detection on the backside of thick steel plates is essential for the safety maintenance of most infrastructures in which they are used. Eddy-current testing (ECT) is a promising method to detect the defects in a steel plate, and inspections at low frequencies are necessary to suppress the skin effect. However, if the frequency is reduced further, the signal from the detection coil also becomes smaller. Therefore, we assessed the optimal frequency for the detection of slit defects on the backside of a 10 mm thick steel plate based on experiments and electromagnetic simulations using the finite-element method. The results suggest that the optimal frequency to detect the defects is approximately 8-10 Hz when the height of the slit exceeds 6 mm. Similarly, in the simulation, the signal was maximized when the frequency was 8-10 Hz, which validates the experimental results. Furthermore, we propose a method to emphasize the deeper defects using multi-frequency data as a fundamental study. The results show that the backside defects are depicted more clearly.",
author = "Wataru Yoshimura and Teruyoshi Sasayama and Keiji Enpuku",
year = "2019",
month = "7",
day = "1",
doi = "10.1109/TMAG.2019.2896590",
language = "English",
volume = "55",
journal = "IEEE Transactions on Magnetics",
issn = "0018-9464",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "7",

}

TY - JOUR

T1 - Optimal Frequency of Low-Frequency Eddy-Current Testing for Detecting Defects on the Backside of Thick Steel Plates

AU - Yoshimura, Wataru

AU - Sasayama, Teruyoshi

AU - Enpuku, Keiji

PY - 2019/7/1

Y1 - 2019/7/1

N2 - Defect detection on the backside of thick steel plates is essential for the safety maintenance of most infrastructures in which they are used. Eddy-current testing (ECT) is a promising method to detect the defects in a steel plate, and inspections at low frequencies are necessary to suppress the skin effect. However, if the frequency is reduced further, the signal from the detection coil also becomes smaller. Therefore, we assessed the optimal frequency for the detection of slit defects on the backside of a 10 mm thick steel plate based on experiments and electromagnetic simulations using the finite-element method. The results suggest that the optimal frequency to detect the defects is approximately 8-10 Hz when the height of the slit exceeds 6 mm. Similarly, in the simulation, the signal was maximized when the frequency was 8-10 Hz, which validates the experimental results. Furthermore, we propose a method to emphasize the deeper defects using multi-frequency data as a fundamental study. The results show that the backside defects are depicted more clearly.

AB - Defect detection on the backside of thick steel plates is essential for the safety maintenance of most infrastructures in which they are used. Eddy-current testing (ECT) is a promising method to detect the defects in a steel plate, and inspections at low frequencies are necessary to suppress the skin effect. However, if the frequency is reduced further, the signal from the detection coil also becomes smaller. Therefore, we assessed the optimal frequency for the detection of slit defects on the backside of a 10 mm thick steel plate based on experiments and electromagnetic simulations using the finite-element method. The results suggest that the optimal frequency to detect the defects is approximately 8-10 Hz when the height of the slit exceeds 6 mm. Similarly, in the simulation, the signal was maximized when the frequency was 8-10 Hz, which validates the experimental results. Furthermore, we propose a method to emphasize the deeper defects using multi-frequency data as a fundamental study. The results show that the backside defects are depicted more clearly.

UR - http://www.scopus.com/inward/record.url?scp=85067806730&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85067806730&partnerID=8YFLogxK

U2 - 10.1109/TMAG.2019.2896590

DO - 10.1109/TMAG.2019.2896590

M3 - Article

VL - 55

JO - IEEE Transactions on Magnetics

JF - IEEE Transactions on Magnetics

SN - 0018-9464

IS - 7

M1 - 8645817

ER -