Overview on the IFMIF test cell development

V. Heinzel, P. Bem, E. Esposito, S. Gordeev, U. Fischer, A. Moeslang, S. Simakov, A. Shimizu, M. Sugimoto, I. Tiseanu, P. Vladimirov, Yukinobu Watanabe, T. Yutani

研究成果: ジャーナルへの寄稿Conference article

8 引用 (Scopus)

抄録

The major components of the test cell are the three test modules, the shield plugs and the test cell covers. The existing drawings of the IFMIF test cell and the internals were put together to have a common basis for discussion. The high-flux-test-module was redesigned. The rigs were designed with a flat plate geometry. They are equipped with an electric heater system, with which the temperatures in the specimens stack can be kept at temperature levels between 250 and 650 °C within a tolerance of 30 °C. The temperature level of each rig can be adjusted independently. First result of the optimization of the medium-flux-test-module are also described.

元の言語英語
ページ(範囲)223-227
ページ数5
ジャーナルJournal of Nuclear Materials
329-333
発行部数1-3 PART A
DOI
出版物ステータス出版済み - 8 1 2004
イベントProceedings of the 11th Conference on Fusion Research - Kyoto, 日本
継続期間: 12 7 200312 12 2003

Fingerprint

cells
Fluxes
modules
Temperature
Geometry
flat plates
plugs
heaters
temperature
optimization
geometry

All Science Journal Classification (ASJC) codes

  • Nuclear and High Energy Physics
  • Materials Science(all)
  • Nuclear Energy and Engineering

これを引用

Heinzel, V., Bem, P., Esposito, E., Gordeev, S., Fischer, U., Moeslang, A., ... Yutani, T. (2004). Overview on the IFMIF test cell development. Journal of Nuclear Materials, 329-333(1-3 PART A), 223-227. https://doi.org/10.1016/j.jnucmat.2004.04.341

Overview on the IFMIF test cell development. / Heinzel, V.; Bem, P.; Esposito, E.; Gordeev, S.; Fischer, U.; Moeslang, A.; Simakov, S.; Shimizu, A.; Sugimoto, M.; Tiseanu, I.; Vladimirov, P.; Watanabe, Yukinobu; Yutani, T.

:: Journal of Nuclear Materials, 巻 329-333, 番号 1-3 PART A, 01.08.2004, p. 223-227.

研究成果: ジャーナルへの寄稿Conference article

Heinzel, V, Bem, P, Esposito, E, Gordeev, S, Fischer, U, Moeslang, A, Simakov, S, Shimizu, A, Sugimoto, M, Tiseanu, I, Vladimirov, P, Watanabe, Y & Yutani, T 2004, 'Overview on the IFMIF test cell development', Journal of Nuclear Materials, 巻. 329-333, 番号 1-3 PART A, pp. 223-227. https://doi.org/10.1016/j.jnucmat.2004.04.341
Heinzel V, Bem P, Esposito E, Gordeev S, Fischer U, Moeslang A その他. Overview on the IFMIF test cell development. Journal of Nuclear Materials. 2004 8 1;329-333(1-3 PART A):223-227. https://doi.org/10.1016/j.jnucmat.2004.04.341
Heinzel, V. ; Bem, P. ; Esposito, E. ; Gordeev, S. ; Fischer, U. ; Moeslang, A. ; Simakov, S. ; Shimizu, A. ; Sugimoto, M. ; Tiseanu, I. ; Vladimirov, P. ; Watanabe, Yukinobu ; Yutani, T. / Overview on the IFMIF test cell development. :: Journal of Nuclear Materials. 2004 ; 巻 329-333, 番号 1-3 PART A. pp. 223-227.
@article{bbcb7914bd864ef6b5913621290d0d8d,
title = "Overview on the IFMIF test cell development",
abstract = "The major components of the test cell are the three test modules, the shield plugs and the test cell covers. The existing drawings of the IFMIF test cell and the internals were put together to have a common basis for discussion. The high-flux-test-module was redesigned. The rigs were designed with a flat plate geometry. They are equipped with an electric heater system, with which the temperatures in the specimens stack can be kept at temperature levels between 250 and 650 °C within a tolerance of 30 °C. The temperature level of each rig can be adjusted independently. First result of the optimization of the medium-flux-test-module are also described.",
author = "V. Heinzel and P. Bem and E. Esposito and S. Gordeev and U. Fischer and A. Moeslang and S. Simakov and A. Shimizu and M. Sugimoto and I. Tiseanu and P. Vladimirov and Yukinobu Watanabe and T. Yutani",
year = "2004",
month = "8",
day = "1",
doi = "10.1016/j.jnucmat.2004.04.341",
language = "English",
volume = "329-333",
pages = "223--227",
journal = "Journal of Nuclear Materials",
issn = "0022-3115",
publisher = "Elsevier",
number = "1-3 PART A",

}

TY - JOUR

T1 - Overview on the IFMIF test cell development

AU - Heinzel, V.

AU - Bem, P.

AU - Esposito, E.

AU - Gordeev, S.

AU - Fischer, U.

AU - Moeslang, A.

AU - Simakov, S.

AU - Shimizu, A.

AU - Sugimoto, M.

AU - Tiseanu, I.

AU - Vladimirov, P.

AU - Watanabe, Yukinobu

AU - Yutani, T.

PY - 2004/8/1

Y1 - 2004/8/1

N2 - The major components of the test cell are the three test modules, the shield plugs and the test cell covers. The existing drawings of the IFMIF test cell and the internals were put together to have a common basis for discussion. The high-flux-test-module was redesigned. The rigs were designed with a flat plate geometry. They are equipped with an electric heater system, with which the temperatures in the specimens stack can be kept at temperature levels between 250 and 650 °C within a tolerance of 30 °C. The temperature level of each rig can be adjusted independently. First result of the optimization of the medium-flux-test-module are also described.

AB - The major components of the test cell are the three test modules, the shield plugs and the test cell covers. The existing drawings of the IFMIF test cell and the internals were put together to have a common basis for discussion. The high-flux-test-module was redesigned. The rigs were designed with a flat plate geometry. They are equipped with an electric heater system, with which the temperatures in the specimens stack can be kept at temperature levels between 250 and 650 °C within a tolerance of 30 °C. The temperature level of each rig can be adjusted independently. First result of the optimization of the medium-flux-test-module are also described.

UR - http://www.scopus.com/inward/record.url?scp=3343022811&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=3343022811&partnerID=8YFLogxK

U2 - 10.1016/j.jnucmat.2004.04.341

DO - 10.1016/j.jnucmat.2004.04.341

M3 - Conference article

AN - SCOPUS:3343022811

VL - 329-333

SP - 223

EP - 227

JO - Journal of Nuclear Materials

JF - Journal of Nuclear Materials

SN - 0022-3115

IS - 1-3 PART A

ER -