Oxygen permeability in cracked concrete reinforced with plain and deformed bars

T. U. Mohammed, N. Otsuki, Hidenori Hamada

研究成果: ジャーナルへの寄稿記事

9 引用 (Scopus)

抄録

Deformed bars are commonly used as reinforcing bars because of its good bonding ability compared to plain (smooth or round) bars. However, only a few studies were carried out comparing the corrosion performance of plain and deformed bars. With this background, the authors carried out detailed investigations on the corrosion of plain and deformed bars. Here, the results of oxygen permeability of multicracked concrete beams reinforced with plain and deformed bars are presented. For this, reinforced concrete beams of size 150×150×1250 mm were made with plain and deformed bars separately. In each beam, a steel bar specially made with segmented steel elements was embedded to measure the distribution of oxygen permeability along the beam after cracking. The cracking load was kept the same for the beams. W/C was 0.5. It was found that the oxygen permeability of cracked concrete reinforced with deformed bars is significantly higher than one reinforced with plain bars. The results indicate that deformed bars are more prone to corrosion than plain bars in cracked concrete.

元の言語英語
ページ(範囲)829-834
ページ数6
ジャーナルCement and Concrete Research
31
発行部数5
DOI
出版物ステータス出版済み - 5 1 2001
外部発表Yes

Fingerprint

Reinforced concrete
Oxygen
Steel
Corrosion
Concretes
Chemical elements

All Science Journal Classification (ASJC) codes

  • Building and Construction
  • Materials Science(all)

これを引用

Oxygen permeability in cracked concrete reinforced with plain and deformed bars. / Mohammed, T. U.; Otsuki, N.; Hamada, Hidenori.

:: Cement and Concrete Research, 巻 31, 番号 5, 01.05.2001, p. 829-834.

研究成果: ジャーナルへの寄稿記事

@article{f146e923aac64de7966767037c3028a3,
title = "Oxygen permeability in cracked concrete reinforced with plain and deformed bars",
abstract = "Deformed bars are commonly used as reinforcing bars because of its good bonding ability compared to plain (smooth or round) bars. However, only a few studies were carried out comparing the corrosion performance of plain and deformed bars. With this background, the authors carried out detailed investigations on the corrosion of plain and deformed bars. Here, the results of oxygen permeability of multicracked concrete beams reinforced with plain and deformed bars are presented. For this, reinforced concrete beams of size 150×150×1250 mm were made with plain and deformed bars separately. In each beam, a steel bar specially made with segmented steel elements was embedded to measure the distribution of oxygen permeability along the beam after cracking. The cracking load was kept the same for the beams. W/C was 0.5. It was found that the oxygen permeability of cracked concrete reinforced with deformed bars is significantly higher than one reinforced with plain bars. The results indicate that deformed bars are more prone to corrosion than plain bars in cracked concrete.",
author = "Mohammed, {T. U.} and N. Otsuki and Hidenori Hamada",
year = "2001",
month = "5",
day = "1",
doi = "10.1016/S0008-8846(01)00482-3",
language = "English",
volume = "31",
pages = "829--834",
journal = "Cement and Concrete Research",
issn = "0008-8846",
publisher = "Elsevier Limited",
number = "5",

}

TY - JOUR

T1 - Oxygen permeability in cracked concrete reinforced with plain and deformed bars

AU - Mohammed, T. U.

AU - Otsuki, N.

AU - Hamada, Hidenori

PY - 2001/5/1

Y1 - 2001/5/1

N2 - Deformed bars are commonly used as reinforcing bars because of its good bonding ability compared to plain (smooth or round) bars. However, only a few studies were carried out comparing the corrosion performance of plain and deformed bars. With this background, the authors carried out detailed investigations on the corrosion of plain and deformed bars. Here, the results of oxygen permeability of multicracked concrete beams reinforced with plain and deformed bars are presented. For this, reinforced concrete beams of size 150×150×1250 mm were made with plain and deformed bars separately. In each beam, a steel bar specially made with segmented steel elements was embedded to measure the distribution of oxygen permeability along the beam after cracking. The cracking load was kept the same for the beams. W/C was 0.5. It was found that the oxygen permeability of cracked concrete reinforced with deformed bars is significantly higher than one reinforced with plain bars. The results indicate that deformed bars are more prone to corrosion than plain bars in cracked concrete.

AB - Deformed bars are commonly used as reinforcing bars because of its good bonding ability compared to plain (smooth or round) bars. However, only a few studies were carried out comparing the corrosion performance of plain and deformed bars. With this background, the authors carried out detailed investigations on the corrosion of plain and deformed bars. Here, the results of oxygen permeability of multicracked concrete beams reinforced with plain and deformed bars are presented. For this, reinforced concrete beams of size 150×150×1250 mm were made with plain and deformed bars separately. In each beam, a steel bar specially made with segmented steel elements was embedded to measure the distribution of oxygen permeability along the beam after cracking. The cracking load was kept the same for the beams. W/C was 0.5. It was found that the oxygen permeability of cracked concrete reinforced with deformed bars is significantly higher than one reinforced with plain bars. The results indicate that deformed bars are more prone to corrosion than plain bars in cracked concrete.

UR - http://www.scopus.com/inward/record.url?scp=0035330937&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035330937&partnerID=8YFLogxK

U2 - 10.1016/S0008-8846(01)00482-3

DO - 10.1016/S0008-8846(01)00482-3

M3 - Article

AN - SCOPUS:0035330937

VL - 31

SP - 829

EP - 834

JO - Cement and Concrete Research

JF - Cement and Concrete Research

SN - 0008-8846

IS - 5

ER -