PD characteristics and mechanisms in artificial air-filled voids at room and liquid nitrogen temperatures

S. Tsuru, M. Nakamura, T. Mine, K. Sakai, J. Suehiro, M. Hara

研究成果: Contribution to journalArticle査読

8 被引用数 (Scopus)

抄録

In this study, partial discharge (PD) characteristics in artificial air-filled voids at room and liquid nitrogen temperatures were investigated experimentally. It was found that minimum PD inception voltage at liquid nitrogen temperature (77 K) decreased with decrease in ambient temperature due to condensation of oxygen in the void. By observation of PD current pulses and light images, it was found that there were three modes of discharge: streamer, Townsend and glow-like discharges in PD at room and liquid nitrogen temperatures. Especially the mode at liquid nitrogen temperature changes markedly with the stress time.

本文言語英語
ページ(範囲)43-50
ページ数8
ジャーナルIEEE Transactions on Dielectrics and Electrical Insulation
6
1
DOI
出版ステータス出版済み - 1999

All Science Journal Classification (ASJC) codes

  • Electrical and Electronic Engineering