Performance Test of gPhone (#123, #126, and #127) in Kyoto and ITB Jatinangor

E. J. Wahyudi, Y. Fukuda, Jun Nishijima, M. Itakura

研究成果: ジャーナルへの寄稿Conference article

抄録

Gravity team of ITB, Kyoto University, and Kyushu University plan to carry out super hybrid measurement to monitor Carbon Capture Storage (CCS) injection in Gundih. During preparation stage and baseline survey before injection phase, gravity team analyze gPhone performance. Performance test of gPhone gravimeters in 2014 conducted in Kyoto and Jatinangor (three gPhone (#123, #126, and #127) placed in the same location). The tidal analysis program BAYTAP-G was used to decompose the gravity data into four components (tidal, trend, irregular, and response for auxiliary data). Response component in Kyoto relatively has lower frequency compare to Jatinangor, due to differences of the two measurement location. Response component from the longest time recording data (gPhone #123) give similiar pattern as gPhone #126, while gPhone #127 slightly different. Average standard deviation of the response component of three gPhone (#123, #126, and #127) respectively were 0.8, 1.0, and 1.9 μGal. Best drift achieved from this test show possibility to reach -4 to 5 pGal/day. Although gPhone #126 records different trend, but from tidal analysis comparison shows similiarity with gPhone #123.

元の言語英語
記事番号012033
ジャーナルJournal of Physics: Conference Series
739
発行部数1
DOI
出版物ステータス出版済み - 9 23 2016
イベント6th Asian Physics Symposium 2015, APS 2015 - Bandung, インドネシア
継続期間: 8 19 20158 20 2015

Fingerprint

performance tests
gravitation
injection
trends
gravimeters
data recording
standard deviation
low frequencies
preparation
carbon

All Science Journal Classification (ASJC) codes

  • Physics and Astronomy(all)

これを引用

Performance Test of gPhone (#123, #126, and #127) in Kyoto and ITB Jatinangor. / Wahyudi, E. J.; Fukuda, Y.; Nishijima, Jun; Itakura, M.

:: Journal of Physics: Conference Series, 巻 739, 番号 1, 012033, 23.09.2016.

研究成果: ジャーナルへの寄稿Conference article

@article{cae2a2bcf21044db9a08564362d49f3e,
title = "Performance Test of gPhone (#123, #126, and #127) in Kyoto and ITB Jatinangor",
abstract = "Gravity team of ITB, Kyoto University, and Kyushu University plan to carry out super hybrid measurement to monitor Carbon Capture Storage (CCS) injection in Gundih. During preparation stage and baseline survey before injection phase, gravity team analyze gPhone performance. Performance test of gPhone gravimeters in 2014 conducted in Kyoto and Jatinangor (three gPhone (#123, #126, and #127) placed in the same location). The tidal analysis program BAYTAP-G was used to decompose the gravity data into four components (tidal, trend, irregular, and response for auxiliary data). Response component in Kyoto relatively has lower frequency compare to Jatinangor, due to differences of the two measurement location. Response component from the longest time recording data (gPhone #123) give similiar pattern as gPhone #126, while gPhone #127 slightly different. Average standard deviation of the response component of three gPhone (#123, #126, and #127) respectively were 0.8, 1.0, and 1.9 μGal. Best drift achieved from this test show possibility to reach -4 to 5 pGal/day. Although gPhone #126 records different trend, but from tidal analysis comparison shows similiarity with gPhone #123.",
author = "Wahyudi, {E. J.} and Y. Fukuda and Jun Nishijima and M. Itakura",
year = "2016",
month = "9",
day = "23",
doi = "10.1088/1742-6596/739/1/012033",
language = "English",
volume = "739",
journal = "Journal of Physics: Conference Series",
issn = "1742-6588",
publisher = "IOP Publishing Ltd.",
number = "1",

}

TY - JOUR

T1 - Performance Test of gPhone (#123, #126, and #127) in Kyoto and ITB Jatinangor

AU - Wahyudi, E. J.

AU - Fukuda, Y.

AU - Nishijima, Jun

AU - Itakura, M.

PY - 2016/9/23

Y1 - 2016/9/23

N2 - Gravity team of ITB, Kyoto University, and Kyushu University plan to carry out super hybrid measurement to monitor Carbon Capture Storage (CCS) injection in Gundih. During preparation stage and baseline survey before injection phase, gravity team analyze gPhone performance. Performance test of gPhone gravimeters in 2014 conducted in Kyoto and Jatinangor (three gPhone (#123, #126, and #127) placed in the same location). The tidal analysis program BAYTAP-G was used to decompose the gravity data into four components (tidal, trend, irregular, and response for auxiliary data). Response component in Kyoto relatively has lower frequency compare to Jatinangor, due to differences of the two measurement location. Response component from the longest time recording data (gPhone #123) give similiar pattern as gPhone #126, while gPhone #127 slightly different. Average standard deviation of the response component of three gPhone (#123, #126, and #127) respectively were 0.8, 1.0, and 1.9 μGal. Best drift achieved from this test show possibility to reach -4 to 5 pGal/day. Although gPhone #126 records different trend, but from tidal analysis comparison shows similiarity with gPhone #123.

AB - Gravity team of ITB, Kyoto University, and Kyushu University plan to carry out super hybrid measurement to monitor Carbon Capture Storage (CCS) injection in Gundih. During preparation stage and baseline survey before injection phase, gravity team analyze gPhone performance. Performance test of gPhone gravimeters in 2014 conducted in Kyoto and Jatinangor (three gPhone (#123, #126, and #127) placed in the same location). The tidal analysis program BAYTAP-G was used to decompose the gravity data into four components (tidal, trend, irregular, and response for auxiliary data). Response component in Kyoto relatively has lower frequency compare to Jatinangor, due to differences of the two measurement location. Response component from the longest time recording data (gPhone #123) give similiar pattern as gPhone #126, while gPhone #127 slightly different. Average standard deviation of the response component of three gPhone (#123, #126, and #127) respectively were 0.8, 1.0, and 1.9 μGal. Best drift achieved from this test show possibility to reach -4 to 5 pGal/day. Although gPhone #126 records different trend, but from tidal analysis comparison shows similiarity with gPhone #123.

UR - http://www.scopus.com/inward/record.url?scp=84991497596&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84991497596&partnerID=8YFLogxK

U2 - 10.1088/1742-6596/739/1/012033

DO - 10.1088/1742-6596/739/1/012033

M3 - Conference article

VL - 739

JO - Journal of Physics: Conference Series

JF - Journal of Physics: Conference Series

SN - 1742-6588

IS - 1

M1 - 012033

ER -