Possibility of sialographic sonography

A doppler phantom study

研究成果: ジャーナルへの寄稿記事

2 引用 (Scopus)

抄録

Objectives. The purpose of this study was to develop a new diagnostic method that has the merits of both sialography and sonography. Study design. Saline solution and various contrast media (Urografin 76%; 100%, 90%, and 67% Lipiodol Ultra-Fluide; 5% and 1% barium sulfate; and Levovist) were injected into thin tubes at a rate of approximately 0.001 to 0.1 mL/s. The relation-ship between the Doppler signal intensity and the kind, concentration, and velocity of the fluid was analyzed. Results. Levovist, 90% and 67% Lipiodol Ultra-Fluide, and the barium sulfate solutions produced Doppler signals. The mixture of Lipiodol Ultra-Fluide and saline solution produced high signals at any concentration, in contrast with the barium sulfate solutions. Signals could be observed at any speed, from the speed of normal sialography down to 0.001 mL/s, and there was a proportional relationship between signal intensity and velocity for all fluids producing signals. Conclusion. The fact that we could obtain high signals with several fluids indicates potential clinical diagnostic usefulness of sialographic sonography.

元の言語英語
ページ(範囲)719-727
ページ数9
ジャーナルOral surgery, oral medicine, oral pathology, oral radiology, and endodontics
91
発行部数6
DOI
出版物ステータス出版済み - 1 1 2001

Fingerprint

Barium Sulfate
Ethiodized Oil
Sialography
Ultrasonography
Sodium Chloride
Diatrizoate Meglumine
Ships
Contrast Media
SHU 508

All Science Journal Classification (ASJC) codes

  • Surgery
  • Oral Surgery
  • Otorhinolaryngology
  • Dentistry(all)

これを引用

Possibility of sialographic sonography : A doppler phantom study. / Shimizu, Mayumi; Tokumori, Kenji; Okamura, Kazutoshi; Chikui, Toru; Yoshiura, Kazunori; Kanda, Shigenobu.

:: Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics, 巻 91, 番号 6, 01.01.2001, p. 719-727.

研究成果: ジャーナルへの寄稿記事

@article{bd6f2f36a1cf4d998db6c4a4c9660314,
title = "Possibility of sialographic sonography: A doppler phantom study",
abstract = "Objectives. The purpose of this study was to develop a new diagnostic method that has the merits of both sialography and sonography. Study design. Saline solution and various contrast media (Urografin 76{\%}; 100{\%}, 90{\%}, and 67{\%} Lipiodol Ultra-Fluide; 5{\%} and 1{\%} barium sulfate; and Levovist) were injected into thin tubes at a rate of approximately 0.001 to 0.1 mL/s. The relation-ship between the Doppler signal intensity and the kind, concentration, and velocity of the fluid was analyzed. Results. Levovist, 90{\%} and 67{\%} Lipiodol Ultra-Fluide, and the barium sulfate solutions produced Doppler signals. The mixture of Lipiodol Ultra-Fluide and saline solution produced high signals at any concentration, in contrast with the barium sulfate solutions. Signals could be observed at any speed, from the speed of normal sialography down to 0.001 mL/s, and there was a proportional relationship between signal intensity and velocity for all fluids producing signals. Conclusion. The fact that we could obtain high signals with several fluids indicates potential clinical diagnostic usefulness of sialographic sonography.",
author = "Mayumi Shimizu and Kenji Tokumori and Kazutoshi Okamura and Toru Chikui and Kazunori Yoshiura and Shigenobu Kanda",
year = "2001",
month = "1",
day = "1",
doi = "10.1067/moe.2001.113832",
language = "English",
volume = "91",
pages = "719--727",
journal = "Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology",
issn = "2212-4403",
publisher = "Elsevier USA",
number = "6",

}

TY - JOUR

T1 - Possibility of sialographic sonography

T2 - A doppler phantom study

AU - Shimizu, Mayumi

AU - Tokumori, Kenji

AU - Okamura, Kazutoshi

AU - Chikui, Toru

AU - Yoshiura, Kazunori

AU - Kanda, Shigenobu

PY - 2001/1/1

Y1 - 2001/1/1

N2 - Objectives. The purpose of this study was to develop a new diagnostic method that has the merits of both sialography and sonography. Study design. Saline solution and various contrast media (Urografin 76%; 100%, 90%, and 67% Lipiodol Ultra-Fluide; 5% and 1% barium sulfate; and Levovist) were injected into thin tubes at a rate of approximately 0.001 to 0.1 mL/s. The relation-ship between the Doppler signal intensity and the kind, concentration, and velocity of the fluid was analyzed. Results. Levovist, 90% and 67% Lipiodol Ultra-Fluide, and the barium sulfate solutions produced Doppler signals. The mixture of Lipiodol Ultra-Fluide and saline solution produced high signals at any concentration, in contrast with the barium sulfate solutions. Signals could be observed at any speed, from the speed of normal sialography down to 0.001 mL/s, and there was a proportional relationship between signal intensity and velocity for all fluids producing signals. Conclusion. The fact that we could obtain high signals with several fluids indicates potential clinical diagnostic usefulness of sialographic sonography.

AB - Objectives. The purpose of this study was to develop a new diagnostic method that has the merits of both sialography and sonography. Study design. Saline solution and various contrast media (Urografin 76%; 100%, 90%, and 67% Lipiodol Ultra-Fluide; 5% and 1% barium sulfate; and Levovist) were injected into thin tubes at a rate of approximately 0.001 to 0.1 mL/s. The relation-ship between the Doppler signal intensity and the kind, concentration, and velocity of the fluid was analyzed. Results. Levovist, 90% and 67% Lipiodol Ultra-Fluide, and the barium sulfate solutions produced Doppler signals. The mixture of Lipiodol Ultra-Fluide and saline solution produced high signals at any concentration, in contrast with the barium sulfate solutions. Signals could be observed at any speed, from the speed of normal sialography down to 0.001 mL/s, and there was a proportional relationship between signal intensity and velocity for all fluids producing signals. Conclusion. The fact that we could obtain high signals with several fluids indicates potential clinical diagnostic usefulness of sialographic sonography.

UR - http://www.scopus.com/inward/record.url?scp=0035379675&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035379675&partnerID=8YFLogxK

U2 - 10.1067/moe.2001.113832

DO - 10.1067/moe.2001.113832

M3 - Article

VL - 91

SP - 719

EP - 727

JO - Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology

JF - Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology

SN - 2212-4403

IS - 6

ER -