T1 - Potential measurements with heavy ion beam probe system on LHD
AU - Shimizu, A.
AU - Ido, T.
AU - Nakamura, S.
AU - Toi, K.
AU - Nishiura, M.
AU - Kato, S.
N1 - Funding Information:
The authors thank the scientific and technical staff of LHD for the continuous support. This work was supported in part by the Grant-in-Aid for Scientific Research from JSPS (Grant No. 21360457) and by the LHD project budget (Grant No. NIFS09ULBB505,515).
PY - 2010/10
Y1 - 2010/10
N2 - The heavy ion beam probe system in the Large Helical Device (LHD) was improved as follows. At first, the additional new sweeper was installed into the diagnostic port to extend the observable region. By using this sweeper, the potential profile was measured in a wider minor radius range than in previous experiments, in the case of outward shifted magnetic configuration of LHD. Next, the real time control system was installed to control the probe beam orbit for measuring the potential in plasma with large plasma current. In this system, a digital signal processor was used to control the probe beam in real time. The system worked well in the fixed position observation mode. In the sweeping mode for profile measurement, this control system became unstable. The details of this system and the experimental results are reported in this article.
AB - The heavy ion beam probe system in the Large Helical Device (LHD) was improved as follows. At first, the additional new sweeper was installed into the diagnostic port to extend the observable region. By using this sweeper, the potential profile was measured in a wider minor radius range than in previous experiments, in the case of outward shifted magnetic configuration of LHD. Next, the real time control system was installed to control the probe beam orbit for measuring the potential in plasma with large plasma current. In this system, a digital signal processor was used to control the probe beam in real time. The system worked well in the fixed position observation mode. In the sweeping mode for profile measurement, this control system became unstable. The details of this system and the experimental results are reported in this article.
UR - http://www.scopus.com/inward/record.url?scp=78149440716&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=78149440716&partnerID=8YFLogxK
U2 - 10.1063/1.3491317
DO - 10.1063/1.3491317
M3 - Article
C2 - 21033999
AN - SCOPUS:78149440716
SN - 0034-6748
VL - 81
JO - Review of Scientific Instruments
JF - Review of Scientific Instruments
IS - 10
M1 - 10E138
ER -