N2 - Factors responsible for the success or failure of orthodontic mini-implants (OMIs) in clinical settings are unclear. Failure of OMIs was found to be associated with increased maximum principal strain (MaxPN) when assessed using the subject-specific finite element (FE) modeling technique. The purpose of the present study was to identify factors that increase MaxPN and thereby predispose the OMI to failure. Using the FE method, MaxPN was calculated around 28 OMIs placed in orthodontic patients, 6 of which failed during the first 5 months. Sixteen potential risk factors related to patients or to OMI position were measured on computerized tomographic images or calculated in FE models. The impact of these factors on MaxPN was verified using regression analysis. Three factors were found to have significant nonlinear relationships with MaxPN: cortical bone quality, vertical angulation of the OMI, and proximity of the OMI to the tooth in the direction of force. In conclusion, failure of an OMI is a multifactorial problem, and position and angulation of the implant are among the affecting factors. Slight apical inclination and positioning at least 1 mm off the root in the direction of force may significantly decrease failure probability.
AB - Factors responsible for the success or failure of orthodontic mini-implants (OMIs) in clinical settings are unclear. Failure of OMIs was found to be associated with increased maximum principal strain (MaxPN) when assessed using the subject-specific finite element (FE) modeling technique. The purpose of the present study was to identify factors that increase MaxPN and thereby predispose the OMI to failure. Using the FE method, MaxPN was calculated around 28 OMIs placed in orthodontic patients, 6 of which failed during the first 5 months. Sixteen potential risk factors related to patients or to OMI position were measured on computerized tomographic images or calculated in FE models. The impact of these factors on MaxPN was verified using regression analysis. Three factors were found to have significant nonlinear relationships with MaxPN: cortical bone quality, vertical angulation of the OMI, and proximity of the OMI to the tooth in the direction of force. In conclusion, failure of an OMI is a multifactorial problem, and position and angulation of the implant are among the affecting factors. Slight apical inclination and positioning at least 1 mm off the root in the direction of force may significantly decrease failure probability.
UR - http://www.scopus.com/inward/record.url?scp=84961201508&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84961201508&partnerID=8YFLogxK
U2 - 10.1007/s10439-016-1584-8
DO - 10.1007/s10439-016-1584-8
M3 - Article
C2 - 26983844
AN - SCOPUS:84961201508
SN - 0090-6964
VL - 44
SP - 2948
EP - 2956
JO - Annals of Biomedical Engineering
JF - Annals of Biomedical Engineering
IS - 10
ER -