Pretreatment of cell membranes for improved electropermeabilization- assisted dielectrophoretic impedance measurement

Michihiko Nakano, Ryo Hamada, Hiroyuki Takayama, Yasuhiko Shonishi, Takafumi Hisajima, Lina Mao, Junya Suehiro

研究成果: ジャーナルへの寄稿記事

1 引用 (Scopus)

抄録

We improved our previously reported highly sensitive bacteria detection method called electropermeabilization-assisted dielectrophoretic impedance measurement (EPA-DEPIM), which counts the number of bacteria by measuring changes in impedance. EPA-DEPIM involves two processes: collection of bacteria by dielectrophoresis (DEP), followed by electropermeabilization (EP) of the cell membranes. In DEP, bacterial cells in aqueous solution are collected on microelectrodes by the dielectrophoretic force. In EP, a pulse-like rectangular wave is applied to the collected cells to disrupt their membranes. This increases the signal sensitivity because the disrupted membranes release intracellular ions that increase the change in impedance. However, the pulse-like EP wave creates a strong electric field that causes metal ions to be released from the microelectrodes, increasing the blank signal to levels comparable to that for a low-concentration Escherichia coli suspension (10 2 cells/ml). To address this problem, we demonstrated the efficacy of two types of pretreatment applied before the EP wave: chemical pretreatment by exposure to hydrogen peroxide, and physical pretreatment by a small pulse-like voltage. Both pretreatments successfully intensified the change in impedance even at a lower EP voltage.

元の言語英語
ページ(範囲)676-681
ページ数6
ジャーナルSensors and Actuators, B: Chemical
173
DOI
出版物ステータス出版済み - 10 1 2012

Fingerprint

impedance measurement
Cell membranes
pretreatment
Bacteria
Microelectrodes
bacteria
Electrophoresis
impedance
Membranes
pulses
cells
Electric potential
membranes
Hydrogen peroxide
Escherichia coli
Hydrogen Peroxide
Metal ions
Suspensions
blanks
Escherichia

All Science Journal Classification (ASJC) codes

  • Instrumentation
  • Materials Chemistry
  • Surfaces, Coatings and Films
  • Metals and Alloys
  • Electronic, Optical and Magnetic Materials
  • Condensed Matter Physics
  • Electrical and Electronic Engineering

これを引用

Pretreatment of cell membranes for improved electropermeabilization- assisted dielectrophoretic impedance measurement. / Nakano, Michihiko; Hamada, Ryo; Takayama, Hiroyuki; Shonishi, Yasuhiko; Hisajima, Takafumi; Mao, Lina; Suehiro, Junya.

:: Sensors and Actuators, B: Chemical, 巻 173, 01.10.2012, p. 676-681.

研究成果: ジャーナルへの寄稿記事

Nakano, Michihiko ; Hamada, Ryo ; Takayama, Hiroyuki ; Shonishi, Yasuhiko ; Hisajima, Takafumi ; Mao, Lina ; Suehiro, Junya. / Pretreatment of cell membranes for improved electropermeabilization- assisted dielectrophoretic impedance measurement. :: Sensors and Actuators, B: Chemical. 2012 ; 巻 173. pp. 676-681.
@article{d5cd7a9a65c04d6bb11f938a379f6749,
title = "Pretreatment of cell membranes for improved electropermeabilization- assisted dielectrophoretic impedance measurement",
abstract = "We improved our previously reported highly sensitive bacteria detection method called electropermeabilization-assisted dielectrophoretic impedance measurement (EPA-DEPIM), which counts the number of bacteria by measuring changes in impedance. EPA-DEPIM involves two processes: collection of bacteria by dielectrophoresis (DEP), followed by electropermeabilization (EP) of the cell membranes. In DEP, bacterial cells in aqueous solution are collected on microelectrodes by the dielectrophoretic force. In EP, a pulse-like rectangular wave is applied to the collected cells to disrupt their membranes. This increases the signal sensitivity because the disrupted membranes release intracellular ions that increase the change in impedance. However, the pulse-like EP wave creates a strong electric field that causes metal ions to be released from the microelectrodes, increasing the blank signal to levels comparable to that for a low-concentration Escherichia coli suspension (10 2 cells/ml). To address this problem, we demonstrated the efficacy of two types of pretreatment applied before the EP wave: chemical pretreatment by exposure to hydrogen peroxide, and physical pretreatment by a small pulse-like voltage. Both pretreatments successfully intensified the change in impedance even at a lower EP voltage.",
author = "Michihiko Nakano and Ryo Hamada and Hiroyuki Takayama and Yasuhiko Shonishi and Takafumi Hisajima and Lina Mao and Junya Suehiro",
year = "2012",
month = "10",
day = "1",
doi = "10.1016/j.snb.2012.07.078",
language = "English",
volume = "173",
pages = "676--681",
journal = "Sensors and Actuators, B: Chemical",
issn = "0925-4005",
publisher = "Elsevier",

}

TY - JOUR

T1 - Pretreatment of cell membranes for improved electropermeabilization- assisted dielectrophoretic impedance measurement

AU - Nakano, Michihiko

AU - Hamada, Ryo

AU - Takayama, Hiroyuki

AU - Shonishi, Yasuhiko

AU - Hisajima, Takafumi

AU - Mao, Lina

AU - Suehiro, Junya

PY - 2012/10/1

Y1 - 2012/10/1

N2 - We improved our previously reported highly sensitive bacteria detection method called electropermeabilization-assisted dielectrophoretic impedance measurement (EPA-DEPIM), which counts the number of bacteria by measuring changes in impedance. EPA-DEPIM involves two processes: collection of bacteria by dielectrophoresis (DEP), followed by electropermeabilization (EP) of the cell membranes. In DEP, bacterial cells in aqueous solution are collected on microelectrodes by the dielectrophoretic force. In EP, a pulse-like rectangular wave is applied to the collected cells to disrupt their membranes. This increases the signal sensitivity because the disrupted membranes release intracellular ions that increase the change in impedance. However, the pulse-like EP wave creates a strong electric field that causes metal ions to be released from the microelectrodes, increasing the blank signal to levels comparable to that for a low-concentration Escherichia coli suspension (10 2 cells/ml). To address this problem, we demonstrated the efficacy of two types of pretreatment applied before the EP wave: chemical pretreatment by exposure to hydrogen peroxide, and physical pretreatment by a small pulse-like voltage. Both pretreatments successfully intensified the change in impedance even at a lower EP voltage.

AB - We improved our previously reported highly sensitive bacteria detection method called electropermeabilization-assisted dielectrophoretic impedance measurement (EPA-DEPIM), which counts the number of bacteria by measuring changes in impedance. EPA-DEPIM involves two processes: collection of bacteria by dielectrophoresis (DEP), followed by electropermeabilization (EP) of the cell membranes. In DEP, bacterial cells in aqueous solution are collected on microelectrodes by the dielectrophoretic force. In EP, a pulse-like rectangular wave is applied to the collected cells to disrupt their membranes. This increases the signal sensitivity because the disrupted membranes release intracellular ions that increase the change in impedance. However, the pulse-like EP wave creates a strong electric field that causes metal ions to be released from the microelectrodes, increasing the blank signal to levels comparable to that for a low-concentration Escherichia coli suspension (10 2 cells/ml). To address this problem, we demonstrated the efficacy of two types of pretreatment applied before the EP wave: chemical pretreatment by exposure to hydrogen peroxide, and physical pretreatment by a small pulse-like voltage. Both pretreatments successfully intensified the change in impedance even at a lower EP voltage.

UR - http://www.scopus.com/inward/record.url?scp=84867059342&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84867059342&partnerID=8YFLogxK

U2 - 10.1016/j.snb.2012.07.078

DO - 10.1016/j.snb.2012.07.078

M3 - Article

VL - 173

SP - 676

EP - 681

JO - Sensors and Actuators, B: Chemical

JF - Sensors and Actuators, B: Chemical

SN - 0925-4005

ER -