Rapid determination of trace uranium in liquid wastes from spent nuclear-fuel reprocessing plants using on-line solid-phase extraction/electrochemical detection

Shigeo Taguchi, Naoki Surugaya, Akira Kurosawa, Toshiaki Hiyama, Tatsuhiko Tanaka

研究成果: ジャーナルへの寄稿記事

1 引用 (Scopus)

抄録

An on-line analysis system using a solid-phase extraction column coupled to electrochemical detection has been developed for the rapid determination of small amounts of uranium in liquid waste samples of spent nuclear-fuel reprocessing plants. A sample solution with a concentration of 3 M HNO3 was loaded onto a column: packed with U/TEVA© resin. The interference elements were rinsed by passing 3 M HNO3 through the column. The adsorbed uranium was eluted with 0.1 M HNO3. The eluate was directly introduced into a flow-electrolysis cell. The reduction current of U(VI) → U(V) was monitored and recorded. The uranium concentration was calculated from the relation between the peak current and the concentration of the standard uranium solution. The result of five repeated analyses for a standard solution containing 2.5 μg (0.1 mL at 25 μg mL-1) of uranium was found to be 2.5 ±0.025 μg (mean ±1σ). The detection limit calculated from 3-times the standard deviation of the background current was 56 ng. The analysis time required for one sample was within 5 min. The recoveries of uranium in actual nuclear waste reprocessing solutions were 92~112%.

元の言語英語
ページ(範囲)901-907
ページ数7
ジャーナルbunseki kagaku
58
発行部数10
DOI
出版物ステータス出版済み - 12 22 2009
外部発表Yes

Fingerprint

Nuclear fuel reprocessing
Uranium
Spent fuels
Liquids
Radioactive Waste
Electrolysis
Resins
Recovery

All Science Journal Classification (ASJC) codes

  • Analytical Chemistry

これを引用

Rapid determination of trace uranium in liquid wastes from spent nuclear-fuel reprocessing plants using on-line solid-phase extraction/electrochemical detection. / Taguchi, Shigeo; Surugaya, Naoki; Kurosawa, Akira; Hiyama, Toshiaki; Tanaka, Tatsuhiko.

:: bunseki kagaku, 巻 58, 番号 10, 22.12.2009, p. 901-907.

研究成果: ジャーナルへの寄稿記事

@article{218d130d296144ff8610881d58d18130,
title = "Rapid determination of trace uranium in liquid wastes from spent nuclear-fuel reprocessing plants using on-line solid-phase extraction/electrochemical detection",
abstract = "An on-line analysis system using a solid-phase extraction column coupled to electrochemical detection has been developed for the rapid determination of small amounts of uranium in liquid waste samples of spent nuclear-fuel reprocessing plants. A sample solution with a concentration of 3 M HNO3 was loaded onto a column: packed with U/TEVA{\circledC} resin. The interference elements were rinsed by passing 3 M HNO3 through the column. The adsorbed uranium was eluted with 0.1 M HNO3. The eluate was directly introduced into a flow-electrolysis cell. The reduction current of U(VI) → U(V) was monitored and recorded. The uranium concentration was calculated from the relation between the peak current and the concentration of the standard uranium solution. The result of five repeated analyses for a standard solution containing 2.5 μg (0.1 mL at 25 μg mL-1) of uranium was found to be 2.5 ±0.025 μg (mean ±1σ). The detection limit calculated from 3-times the standard deviation of the background current was 56 ng. The analysis time required for one sample was within 5 min. The recoveries of uranium in actual nuclear waste reprocessing solutions were 92~112{\%}.",
author = "Shigeo Taguchi and Naoki Surugaya and Akira Kurosawa and Toshiaki Hiyama and Tatsuhiko Tanaka",
year = "2009",
month = "12",
day = "22",
doi = "10.2116/bunsekikagaku.58.901",
language = "English",
volume = "58",
pages = "901--907",
journal = "Bunseki Kagaku",
issn = "0525-1931",
publisher = "公益社団法人日本分析化学会",
number = "10",

}

TY - JOUR

T1 - Rapid determination of trace uranium in liquid wastes from spent nuclear-fuel reprocessing plants using on-line solid-phase extraction/electrochemical detection

AU - Taguchi, Shigeo

AU - Surugaya, Naoki

AU - Kurosawa, Akira

AU - Hiyama, Toshiaki

AU - Tanaka, Tatsuhiko

PY - 2009/12/22

Y1 - 2009/12/22

N2 - An on-line analysis system using a solid-phase extraction column coupled to electrochemical detection has been developed for the rapid determination of small amounts of uranium in liquid waste samples of spent nuclear-fuel reprocessing plants. A sample solution with a concentration of 3 M HNO3 was loaded onto a column: packed with U/TEVA© resin. The interference elements were rinsed by passing 3 M HNO3 through the column. The adsorbed uranium was eluted with 0.1 M HNO3. The eluate was directly introduced into a flow-electrolysis cell. The reduction current of U(VI) → U(V) was monitored and recorded. The uranium concentration was calculated from the relation between the peak current and the concentration of the standard uranium solution. The result of five repeated analyses for a standard solution containing 2.5 μg (0.1 mL at 25 μg mL-1) of uranium was found to be 2.5 ±0.025 μg (mean ±1σ). The detection limit calculated from 3-times the standard deviation of the background current was 56 ng. The analysis time required for one sample was within 5 min. The recoveries of uranium in actual nuclear waste reprocessing solutions were 92~112%.

AB - An on-line analysis system using a solid-phase extraction column coupled to electrochemical detection has been developed for the rapid determination of small amounts of uranium in liquid waste samples of spent nuclear-fuel reprocessing plants. A sample solution with a concentration of 3 M HNO3 was loaded onto a column: packed with U/TEVA© resin. The interference elements were rinsed by passing 3 M HNO3 through the column. The adsorbed uranium was eluted with 0.1 M HNO3. The eluate was directly introduced into a flow-electrolysis cell. The reduction current of U(VI) → U(V) was monitored and recorded. The uranium concentration was calculated from the relation between the peak current and the concentration of the standard uranium solution. The result of five repeated analyses for a standard solution containing 2.5 μg (0.1 mL at 25 μg mL-1) of uranium was found to be 2.5 ±0.025 μg (mean ±1σ). The detection limit calculated from 3-times the standard deviation of the background current was 56 ng. The analysis time required for one sample was within 5 min. The recoveries of uranium in actual nuclear waste reprocessing solutions were 92~112%.

UR - http://www.scopus.com/inward/record.url?scp=72149132018&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=72149132018&partnerID=8YFLogxK

U2 - 10.2116/bunsekikagaku.58.901

DO - 10.2116/bunsekikagaku.58.901

M3 - Article

AN - SCOPUS:72149132018

VL - 58

SP - 901

EP - 907

JO - Bunseki Kagaku

JF - Bunseki Kagaku

SN - 0525-1931

IS - 10