Reduction of aerodynamic heating with opposing jet through extended nozzle in high enthalpy flow

Naoki Morimoto, Jang Yeol Yoon, Shigeru Aso, Yasuhiro Tani

研究成果: 著書/レポートタイプへの貢献会議での発言

2 引用 (Scopus)

抄録

Thermal protection efficiency of combinational configuration of the opposing jet and the spike has been investigated. Heat flux distributions on hemispherical-cylindrical test model with various length of the extended nozzle have been measured in free piston shock tunnel. The test results demonstrate that this combinational configuration achieve sufficient thermal protection in smaller amount of jet flow than that of the opposing jet alone. Numerical simulations are also presented to explain the mechanisms of reducing the heat load on the nose part of blunt body.

元の言語英語
ホスト出版物のタイトル52nd Aerospace Sciences Meeting
出版者American Institute of Aeronautics and Astronautics Inc.
ISBN(電子版)9781624102561
出版物ステータス出版済み - 1 1 2014
イベント52nd Aerospace Sciences Meeting 2014 - National Harbor, 米国
継続期間: 1 13 20141 17 2014

出版物シリーズ

名前52nd Aerospace Sciences Meeting

その他

その他52nd Aerospace Sciences Meeting 2014
米国
National Harbor
期間1/13/141/17/14

Fingerprint

Aerodynamic heating
Enthalpy
Nozzles
Thermal load
Pistons
Heat flux
Tunnels
Computer simulation
Hot Temperature

All Science Journal Classification (ASJC) codes

  • Aerospace Engineering

これを引用

Morimoto, N., Yoon, J. Y., Aso, S., & Tani, Y. (2014). Reduction of aerodynamic heating with opposing jet through extended nozzle in high enthalpy flow. : 52nd Aerospace Sciences Meeting (52nd Aerospace Sciences Meeting). American Institute of Aeronautics and Astronautics Inc..

Reduction of aerodynamic heating with opposing jet through extended nozzle in high enthalpy flow. / Morimoto, Naoki; Yoon, Jang Yeol; Aso, Shigeru; Tani, Yasuhiro.

52nd Aerospace Sciences Meeting. American Institute of Aeronautics and Astronautics Inc., 2014. (52nd Aerospace Sciences Meeting).

研究成果: 著書/レポートタイプへの貢献会議での発言

Morimoto, N, Yoon, JY, Aso, S & Tani, Y 2014, Reduction of aerodynamic heating with opposing jet through extended nozzle in high enthalpy flow. : 52nd Aerospace Sciences Meeting. 52nd Aerospace Sciences Meeting, American Institute of Aeronautics and Astronautics Inc., 52nd Aerospace Sciences Meeting 2014, National Harbor, 米国, 1/13/14.
Morimoto N, Yoon JY, Aso S, Tani Y. Reduction of aerodynamic heating with opposing jet through extended nozzle in high enthalpy flow. : 52nd Aerospace Sciences Meeting. American Institute of Aeronautics and Astronautics Inc. 2014. (52nd Aerospace Sciences Meeting).
Morimoto, Naoki ; Yoon, Jang Yeol ; Aso, Shigeru ; Tani, Yasuhiro. / Reduction of aerodynamic heating with opposing jet through extended nozzle in high enthalpy flow. 52nd Aerospace Sciences Meeting. American Institute of Aeronautics and Astronautics Inc., 2014. (52nd Aerospace Sciences Meeting).
@inproceedings{5c2266153e994da7b6ab9aee69d80c82,
title = "Reduction of aerodynamic heating with opposing jet through extended nozzle in high enthalpy flow",
abstract = "Thermal protection efficiency of combinational configuration of the opposing jet and the spike has been investigated. Heat flux distributions on hemispherical-cylindrical test model with various length of the extended nozzle have been measured in free piston shock tunnel. The test results demonstrate that this combinational configuration achieve sufficient thermal protection in smaller amount of jet flow than that of the opposing jet alone. Numerical simulations are also presented to explain the mechanisms of reducing the heat load on the nose part of blunt body.",
author = "Naoki Morimoto and Yoon, {Jang Yeol} and Shigeru Aso and Yasuhiro Tani",
year = "2014",
month = "1",
day = "1",
language = "English",
series = "52nd Aerospace Sciences Meeting",
publisher = "American Institute of Aeronautics and Astronautics Inc.",
booktitle = "52nd Aerospace Sciences Meeting",

}

TY - GEN

T1 - Reduction of aerodynamic heating with opposing jet through extended nozzle in high enthalpy flow

AU - Morimoto, Naoki

AU - Yoon, Jang Yeol

AU - Aso, Shigeru

AU - Tani, Yasuhiro

PY - 2014/1/1

Y1 - 2014/1/1

N2 - Thermal protection efficiency of combinational configuration of the opposing jet and the spike has been investigated. Heat flux distributions on hemispherical-cylindrical test model with various length of the extended nozzle have been measured in free piston shock tunnel. The test results demonstrate that this combinational configuration achieve sufficient thermal protection in smaller amount of jet flow than that of the opposing jet alone. Numerical simulations are also presented to explain the mechanisms of reducing the heat load on the nose part of blunt body.

AB - Thermal protection efficiency of combinational configuration of the opposing jet and the spike has been investigated. Heat flux distributions on hemispherical-cylindrical test model with various length of the extended nozzle have been measured in free piston shock tunnel. The test results demonstrate that this combinational configuration achieve sufficient thermal protection in smaller amount of jet flow than that of the opposing jet alone. Numerical simulations are also presented to explain the mechanisms of reducing the heat load on the nose part of blunt body.

UR - http://www.scopus.com/inward/record.url?scp=84938345576&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84938345576&partnerID=8YFLogxK

M3 - Conference contribution

T3 - 52nd Aerospace Sciences Meeting

BT - 52nd Aerospace Sciences Meeting

PB - American Institute of Aeronautics and Astronautics Inc.

ER -