Reflectance-based monolithic organic pulsemeter device for measuring photoplethysmogram signal

Fahed Elsamnah, Reiji Hattori, Muhamad Affiq, Chang Hoon Shim, Anubha Bilgaiyan, Ryutaro Sugawara

研究成果: 著書/レポートタイプへの貢献会議での発言

2 引用 (Scopus)

抜粋

Photoplethysmogram (PPG) signal is an essential bio-signal that can be used for detecting several heart diseases. It has become fundamental to wearable health monitoring devices. The human vital signs, such as heart rate (HR), Oxygen saturation (SpO2) and respiration rate, can be clearly extracted from the PPG signal. In this paper, we applied reflectance pulse measurement method on an organic optoelectronic device to measure the PPG signal. We fabricated a monolithic device, a red (625nm) organic light-emitting diode (OLED) and an organic photodiode (OPD) sensitive at the aforementioned wavelength. The external quantum efficiency (EQE) of the OLED and the OPD were 7% and 47%, respectively. In this work, we utilized a Bluetooth Low Energy (BLE) for sending the measured PPG signal to the central side, desktop computer. The data traffic of the BLE module was 2 kbps at the minimum connection interval 7.5 ms. The reflectance method showed very good results of (1.5) percent error of the heart rate compared to the commercially reference we obtained.

元の言語英語
ホスト出版物のタイトルI2MTC 2018 - 2018 IEEE International Instrumentation and Measurement Technology Conference
ホスト出版物のサブタイトルDiscovering New Horizons in Instrumentation and Measurement, Proceedings
出版者Institute of Electrical and Electronics Engineers Inc.
ページ1-5
ページ数5
ISBN(電子版)9781538622223
DOI
出版物ステータス出版済み - 7 10 2018
イベント2018 IEEE International Instrumentation and Measurement Technology Conference, I2MTC 2018 - Houston, 米国
継続期間: 5 14 20185 17 2018

出版物シリーズ

名前I2MTC 2018 - 2018 IEEE International Instrumentation and Measurement Technology Conference: Discovering New Horizons in Instrumentation and Measurement, Proceedings

その他

その他2018 IEEE International Instrumentation and Measurement Technology Conference, I2MTC 2018
米国
Houston
期間5/14/185/17/18

    フィンガープリント

All Science Journal Classification (ASJC) codes

  • Safety, Risk, Reliability and Quality
  • Instrumentation

これを引用

Elsamnah, F., Hattori, R., Affiq, M., Shim, C. H., Bilgaiyan, A., & Sugawara, R. (2018). Reflectance-based monolithic organic pulsemeter device for measuring photoplethysmogram signal. : I2MTC 2018 - 2018 IEEE International Instrumentation and Measurement Technology Conference: Discovering New Horizons in Instrumentation and Measurement, Proceedings (pp. 1-5). (I2MTC 2018 - 2018 IEEE International Instrumentation and Measurement Technology Conference: Discovering New Horizons in Instrumentation and Measurement, Proceedings). Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/I2MTC.2018.8409873