Role of carboxyl and amine termination on a boron-doped diamond solution gate field effect transistor (SGFET) for PH sensing

Shaili Falina, Sora Kawai, Nobutaka Oi, Hayate Yamano, Taisuke Kageura, Evi Suaebah, Masafumi Inaba, Yukihiro Shintani, Mohd Syamsul, Hiroshi Kawarada

研究成果: ジャーナルへの寄稿記事

2 引用 (Scopus)

抄録

In this paper, we report on the effect of carboxyl-and amine terminations on a boron-doped diamond surface (BDD) in relation to pH sensitivity. Carboxyl termination was achieved by anodization oxidation in Carmody buffer solution (pH 7). The carboxyl-terminated diamond surface was exposed to nitrogen radicals to generate an amine-terminated surface. The pH sensitivity of the carboxyl-and amine-terminated surfaces was measured from pH 2 to pH 12. The pH sensitivities of the carboxyl-terminated surface at low and high pH are 45 and 3 mV/pH, respectively. The pH sensitivity after amine termination is significantly higher—the pH sensitivities at low and high pH are 65 and 24 mV/pH, respectively. We find that the negatively-charged surface properties of the carboxyl-terminated surface due to ionization of –COOH causes very low pH detection in the high pH region (pH 7–12). In the case of the amine-terminated surface, the surface properties are interchangeable in both acidic and basic solutions; therefore, we observed pH detection at both low and high pH regions. The results presented here may provide molecular-level understanding of surface properties with charged ions in pH solutions. The understanding of these surface terminations on BDD substrate may be useful to design diamond-based biosensors.

元の言語英語
記事番号2178
ジャーナルSensors (Switzerland)
18
発行部数7
DOI
出版物ステータス出版済み - 7 6 2018

Fingerprint

Gates (transistor)
Diamond
Boron
Amines
Diamonds
amines
boron
field effect transistors
diamonds
Surface properties
Surface Properties
sensitivity
surface properties
Biosensors
Ionization
Buffers
Nitrogen
Ions
Oxidation

All Science Journal Classification (ASJC) codes

  • Analytical Chemistry
  • Biochemistry
  • Atomic and Molecular Physics, and Optics
  • Instrumentation
  • Electrical and Electronic Engineering

これを引用

Role of carboxyl and amine termination on a boron-doped diamond solution gate field effect transistor (SGFET) for PH sensing. / Falina, Shaili; Kawai, Sora; Oi, Nobutaka; Yamano, Hayate; Kageura, Taisuke; Suaebah, Evi; Inaba, Masafumi; Shintani, Yukihiro; Syamsul, Mohd; Kawarada, Hiroshi.

:: Sensors (Switzerland), 巻 18, 番号 7, 2178, 06.07.2018.

研究成果: ジャーナルへの寄稿記事

Falina, S, Kawai, S, Oi, N, Yamano, H, Kageura, T, Suaebah, E, Inaba, M, Shintani, Y, Syamsul, M & Kawarada, H 2018, 'Role of carboxyl and amine termination on a boron-doped diamond solution gate field effect transistor (SGFET) for PH sensing', Sensors (Switzerland), 巻. 18, 番号 7, 2178. https://doi.org/10.3390/s18072178
Falina, Shaili ; Kawai, Sora ; Oi, Nobutaka ; Yamano, Hayate ; Kageura, Taisuke ; Suaebah, Evi ; Inaba, Masafumi ; Shintani, Yukihiro ; Syamsul, Mohd ; Kawarada, Hiroshi. / Role of carboxyl and amine termination on a boron-doped diamond solution gate field effect transistor (SGFET) for PH sensing. :: Sensors (Switzerland). 2018 ; 巻 18, 番号 7.
@article{1100c61cb1434d39a7804e29fdefbe24,
title = "Role of carboxyl and amine termination on a boron-doped diamond solution gate field effect transistor (SGFET) for PH sensing",
abstract = "In this paper, we report on the effect of carboxyl-and amine terminations on a boron-doped diamond surface (BDD) in relation to pH sensitivity. Carboxyl termination was achieved by anodization oxidation in Carmody buffer solution (pH 7). The carboxyl-terminated diamond surface was exposed to nitrogen radicals to generate an amine-terminated surface. The pH sensitivity of the carboxyl-and amine-terminated surfaces was measured from pH 2 to pH 12. The pH sensitivities of the carboxyl-terminated surface at low and high pH are 45 and 3 mV/pH, respectively. The pH sensitivity after amine termination is significantly higher—the pH sensitivities at low and high pH are 65 and 24 mV/pH, respectively. We find that the negatively-charged surface properties of the carboxyl-terminated surface due to ionization of –COOH causes very low pH detection in the high pH region (pH 7–12). In the case of the amine-terminated surface, the surface properties are interchangeable in both acidic and basic solutions; therefore, we observed pH detection at both low and high pH regions. The results presented here may provide molecular-level understanding of surface properties with charged ions in pH solutions. The understanding of these surface terminations on BDD substrate may be useful to design diamond-based biosensors.",
author = "Shaili Falina and Sora Kawai and Nobutaka Oi and Hayate Yamano and Taisuke Kageura and Evi Suaebah and Masafumi Inaba and Yukihiro Shintani and Mohd Syamsul and Hiroshi Kawarada",
year = "2018",
month = "7",
day = "6",
doi = "10.3390/s18072178",
language = "English",
volume = "18",
journal = "Sensors",
issn = "1424-3210",
publisher = "Multidisciplinary Digital Publishing Institute (MDPI)",
number = "7",

}

TY - JOUR

T1 - Role of carboxyl and amine termination on a boron-doped diamond solution gate field effect transistor (SGFET) for PH sensing

AU - Falina, Shaili

AU - Kawai, Sora

AU - Oi, Nobutaka

AU - Yamano, Hayate

AU - Kageura, Taisuke

AU - Suaebah, Evi

AU - Inaba, Masafumi

AU - Shintani, Yukihiro

AU - Syamsul, Mohd

AU - Kawarada, Hiroshi

PY - 2018/7/6

Y1 - 2018/7/6

N2 - In this paper, we report on the effect of carboxyl-and amine terminations on a boron-doped diamond surface (BDD) in relation to pH sensitivity. Carboxyl termination was achieved by anodization oxidation in Carmody buffer solution (pH 7). The carboxyl-terminated diamond surface was exposed to nitrogen radicals to generate an amine-terminated surface. The pH sensitivity of the carboxyl-and amine-terminated surfaces was measured from pH 2 to pH 12. The pH sensitivities of the carboxyl-terminated surface at low and high pH are 45 and 3 mV/pH, respectively. The pH sensitivity after amine termination is significantly higher—the pH sensitivities at low and high pH are 65 and 24 mV/pH, respectively. We find that the negatively-charged surface properties of the carboxyl-terminated surface due to ionization of –COOH causes very low pH detection in the high pH region (pH 7–12). In the case of the amine-terminated surface, the surface properties are interchangeable in both acidic and basic solutions; therefore, we observed pH detection at both low and high pH regions. The results presented here may provide molecular-level understanding of surface properties with charged ions in pH solutions. The understanding of these surface terminations on BDD substrate may be useful to design diamond-based biosensors.

AB - In this paper, we report on the effect of carboxyl-and amine terminations on a boron-doped diamond surface (BDD) in relation to pH sensitivity. Carboxyl termination was achieved by anodization oxidation in Carmody buffer solution (pH 7). The carboxyl-terminated diamond surface was exposed to nitrogen radicals to generate an amine-terminated surface. The pH sensitivity of the carboxyl-and amine-terminated surfaces was measured from pH 2 to pH 12. The pH sensitivities of the carboxyl-terminated surface at low and high pH are 45 and 3 mV/pH, respectively. The pH sensitivity after amine termination is significantly higher—the pH sensitivities at low and high pH are 65 and 24 mV/pH, respectively. We find that the negatively-charged surface properties of the carboxyl-terminated surface due to ionization of –COOH causes very low pH detection in the high pH region (pH 7–12). In the case of the amine-terminated surface, the surface properties are interchangeable in both acidic and basic solutions; therefore, we observed pH detection at both low and high pH regions. The results presented here may provide molecular-level understanding of surface properties with charged ions in pH solutions. The understanding of these surface terminations on BDD substrate may be useful to design diamond-based biosensors.

UR - http://www.scopus.com/inward/record.url?scp=85049843795&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85049843795&partnerID=8YFLogxK

U2 - 10.3390/s18072178

DO - 10.3390/s18072178

M3 - Article

AN - SCOPUS:85049843795

VL - 18

JO - Sensors

JF - Sensors

SN - 1424-3210

IS - 7

M1 - 2178

ER -